Technical data
Leuze electronic
MC3x
47
Table 13.6:
Connection
Table 13.7:
Environment
Table 13.8:
Housing
13.3 MSI-MC310 Safety Relay
Table 13.9:
Safety-relevant technical data
Approach actuation directions
In longitudinal axis, left and right
In vertical axis, up and down
In depth, to and from sensor
Min. approach speed of actuator towards sen
-
sor
50 mm/s
Response time
3 ms
Number of connection cable infeeds
1 (connection cable or M8 plug)
Connection type
Connection cable with wire-end sleeves or M8 plug,
each molded to housing
Conductor cross-section (stranded)
4 x 0.35 mm
²
(connection cable)
Ambient temperature, operation
-20 … +70 °C
Vibration, sensitivity acc. to
EN 60947-5-3:2005
Shock, sensitivity acc. to
EN 60947-5-3:2005
Dirt level, external,
in accordance with EN 60947-1
3
EMC compliance
EN 60947-5-3:2005
EN 61000-6-3:2007
EN 61000-6-2:2005
EN 55011:2003
Sensor material
Plastic, glass fiber reinforced (PPS)
Actuator material
Plastic, glass fiber reinforced (PPS)
Dimensions (dimensional drawings)
see chapter 14 „Dimensions and weights“
Protection rating acc. to EN 60529
IP 67
Safety category acc. to EN 13849-1:2008
4,
1 sensor connected
3,
More than 1 sensor connected
Performance Level (PL)
in accordance with EN ISO 13849
-
1:2008
PL e
PL e
PL d
Average probability of a dangerous failure per
hour (PFH
d
)
2.47
×
10
-8
4.29
×
10
-8
1.03
×
10
-7
with mean annual number of switching cycles
performed by the relay (N
op
)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]