Leuze electronic LCAM 408i User Manual Download Page 8

 

First Steps 

2.1 

What’s needed 

Before you start, you will need: 

 

The LCAM 408i 

 

Ethernet cable with connectors M12 X-coded 

– RJ-45, CAT6 

 

Switch (1000BaseT) or direct PC connected with Gigabit Ethernet interface  

 

Streaming video viewer Leuze viewer, VLC or equivalent. 

 

2.2 

What to do 

After unpacking the camera, the following steps for a first use are: 

 

Connect an M12 

– RJ45 Ethernet cable between the LCam and a Ethernetport (PC or switch) 

 

Connect a Cable for Power supply to the other M12 connector 

 

Power up the cable, wait for approx. 1 minute for LCam to boot. If you hear a faint noise, do 
not worry. 

 

Detect the L

cam’s address 

 

Either: Run the program hipca detect.exe' and identify the LCam you want to talk with 

 

Or: Use default fixed address (see below). You may h

ave to change the PC’s IP to an address 

like 192.168.60.101, so it is in the same sub-net 

 

Open Internet browser on the computer 

 

In  the  browser’s  address  line  type  in  the  IP  address  of  the  LCAM  408  in  the  form 
“192.168.60.101” 

 

Watch for the camera’s web server surface to show up, should  appear as  in “Menu  general 
appearance” 

 

Proceed  with  setting  password  and  video  parameters.  For  that  you  need  a  password  (see 
below for default) 

 

Start streaming video 

 

When finished, start the streaming client as shown below. 

 

This  document  gives  an  introduction  into  the  use  of  the  LCAM  408i  with  MJPEG  streaming.  The 
Software API is available on request. 

 

Web Interface 

3.1 

Changing Camera IPs 

Under *Network settings* you can choose between static address assignment and DHCP mode. 

For  static  IP,  fill  out  the  fields  as  needed.  And  press  "Save  data".  To  use  the  new  settings,  pressing 
"Restart network" is needed. 

 

Summary of Contents for LCAM 408i

Page 1: ...LCAM 408i Industrial Ethernet Camera User Manual Revision 1 2...

Page 2: ...s This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and foun...

Page 3: ...local power company If the power supply is broken do not try to fix it by yourself Contact a qualified service technician or your retailer Operation safety Before installing the motherboard and addin...

Page 4: ...face 8 3 1 Changing Camera IPs 8 3 2 Default network settings 9 3 3 Default login data 9 Web interface 9 SSH 9 3 4 Camera Settings 10 3 5 Still image 10 3 6 Streaming 11 3 6 1 Stream data structure 11...

Page 5: ...H 1 1 M12 connectors The M12 connectors on the bottom side are used for Ethernet connection named with SERVICE and the other for Power Supply named with PWR It is an X coded M12 with 8 pins female and...

Page 6: ...system is used to store persistent data 1 5 Optics The lens M12 is mounted behind a protective front glass no optical requirements that cannot be changed be the user The setup the lens focus is done i...

Page 7: ...7 1 6 2 At a Rod 14 20mm with the BT 56 1 or BT 300 1 1 6 3 With a mounting angle The camera can mount to the BT 300W and adjust in different directions...

Page 8: ...fixed address see below You may have to change the PC s IP to an address like 192 168 60 101 so it is in the same sub net Open Internet browser on the computer In the browser s address line type in th...

Page 9: ...101 This is in one of the private IP spaces IP Mask 255 255 0 0 Gateway Not needed for test change for large nets DNS server Not needed for test change for large nets Order number xxx Camera individu...

Page 10: ...effect Sleep between snaps only used in webcam mode not in streaming mode Automatic gain correction enables the automatic exposure control Flicker free exposure if 0 no flicker free exposure is used...

Page 11: ...aching and IP address if not done so on the command line 3 6 1 Stream data structure To access the video data in your own software open a socket to port 5001 of the camera and scan the incoming data f...

Page 12: ...P Protocol allow maximum Pixels up to 2000 Therefore we recommend to use as maximum the picture resolution of 1920x1080 pixel FullHD 3 6 3 Live stream in the browser Softwareversion 45d1eab The LCAM s...

Page 13: ...The LCAM 408i has an internal web server that has the following menus 4 1 Administration 4 1 1 Factory reset 4 1 2 Password selection Here one of the two possible passwords can be selected to be chan...

Page 14: ...14 4 1 3 Password setting Here passwords are changed and set 4 1 4 Reboot System reboot is done without further data and should be finished after a minute...

Page 15: ...eams with the same content on different ports one full size and one scaled down When the image size is set to values smaller than half the linear sensor pixel number see data sheet below binning is en...

Page 16: ...anging the exposure time For values 0 exposure time is limited to multiples of the value Exposure values in between are realized by changing the gain For 50Hz lighting flicker free exposure is realize...

Page 17: ...eters can be set At the moment camera settings can only be changed by the web interface It is possible to change the exposure time the gain of the different color channels image flipping and Bayer mod...

Page 18: ...mounting position of the camera Changes Bayer mode which is fixed yet See below Bayer mode because the flipping will change the starting pixels the Bayer mode the mode has to be adjusted if flipping...

Page 19: ...d DHCP mode For static IP fill out the fields as needed And press Save data To use the new settings pressing Restart network is needed For DHCP mode no addresses are needed they are obtained from the...

Page 20: ...20 4 4 Menu general appearance This image shows the general menu structure 4 5 About Menu The About screen shows data needed for service enquiries or for searching a camera in the network...

Page 21: ...21 5 Appendix Data sheet key data Below you find the key data for the sensor...