Leuze electronic LCAM 408i User Manual Download Page 2

 

 

Revision  Changes 

Date | Name 

1.0 

First Edition 

20.05.2016 | esh 

1.1 

Addition RTSP-Protocol, Live stream in Browser 

04.01.2018 

| esh 

1.2. 

RSTP limits 

30.01.2018 

 

 

DISCLAIMER  

Copyright 

© 2016 Leuze electronic GmbH+Co. KG. The information, data, and figures in this document including 
respective references have been verified and found to be legitimate. In particular in the event of error 
they  may,  therefore,  be  changed  at  any  time  without  prior  notice.  The  complete  risk  inherent  in  the 
utilization of this document or in the results of its utilization shall  be  with the user; to this end,  Leuze 
electronic  GmbH+Co  KG  shall  not  accept  any  liability.  Regardless  of  the  applicability  of  respective 
copyrights, no portion of this document shall be copied, forwarded or stored in a data reception system 
or entered into such systems without the express prior written consent of Leuze electronic GmbH+Co 
KG,  regardless  of  how  such  acts  are  performed  and  what  system  is  used  (electronic,  mechanic, 
photocopying,  recording,  etc.).  All  product  and  company  names  are  registered  trademarks  of  the 
respective companies. 

Our General Business, Delivery, Offer, and Payment Terms and Conditions shall otherwise apply. 

 

Federal communications commission statement 

This device complies with FCC Rules Part 15. Operation is subject to the following two conditions:  

This device may not cause harmful interference, and 

This  device  must  accept  any  interference  received  including  interference  that  may  cause  undesired 

operation. 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B  digital  device, 

pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
manufacturer’s  instructions,  may  cause  harmful  interference  to  radio  communications. 
However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular  installation.  If 
this equipment does cause harmful interference to radio or television reception, which can be 
determined  by  turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try    correct  the 
interference by one or more of the following measures:  

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

The  use  of  shielded  cables  for  connection  of  the  monitor  to  the  graphics  card  is  required  to  assure 

compliance  with  FCC  regulations.  Changes  or  modifications  to  this  unit  not  expressly 
approved 

by  the  party  responsible  for  compliance  could  void  the  user’s  authority  to  operate 

this equipment. 

 

 

 

 

Summary of Contents for LCAM 408i

Page 1: ...LCAM 408i Industrial Ethernet Camera User Manual Revision 1 2...

Page 2: ...s This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and foun...

Page 3: ...local power company If the power supply is broken do not try to fix it by yourself Contact a qualified service technician or your retailer Operation safety Before installing the motherboard and addin...

Page 4: ...face 8 3 1 Changing Camera IPs 8 3 2 Default network settings 9 3 3 Default login data 9 Web interface 9 SSH 9 3 4 Camera Settings 10 3 5 Still image 10 3 6 Streaming 11 3 6 1 Stream data structure 11...

Page 5: ...H 1 1 M12 connectors The M12 connectors on the bottom side are used for Ethernet connection named with SERVICE and the other for Power Supply named with PWR It is an X coded M12 with 8 pins female and...

Page 6: ...system is used to store persistent data 1 5 Optics The lens M12 is mounted behind a protective front glass no optical requirements that cannot be changed be the user The setup the lens focus is done i...

Page 7: ...7 1 6 2 At a Rod 14 20mm with the BT 56 1 or BT 300 1 1 6 3 With a mounting angle The camera can mount to the BT 300W and adjust in different directions...

Page 8: ...fixed address see below You may have to change the PC s IP to an address like 192 168 60 101 so it is in the same sub net Open Internet browser on the computer In the browser s address line type in th...

Page 9: ...101 This is in one of the private IP spaces IP Mask 255 255 0 0 Gateway Not needed for test change for large nets DNS server Not needed for test change for large nets Order number xxx Camera individu...

Page 10: ...effect Sleep between snaps only used in webcam mode not in streaming mode Automatic gain correction enables the automatic exposure control Flicker free exposure if 0 no flicker free exposure is used...

Page 11: ...aching and IP address if not done so on the command line 3 6 1 Stream data structure To access the video data in your own software open a socket to port 5001 of the camera and scan the incoming data f...

Page 12: ...P Protocol allow maximum Pixels up to 2000 Therefore we recommend to use as maximum the picture resolution of 1920x1080 pixel FullHD 3 6 3 Live stream in the browser Softwareversion 45d1eab The LCAM s...

Page 13: ...The LCAM 408i has an internal web server that has the following menus 4 1 Administration 4 1 1 Factory reset 4 1 2 Password selection Here one of the two possible passwords can be selected to be chan...

Page 14: ...14 4 1 3 Password setting Here passwords are changed and set 4 1 4 Reboot System reboot is done without further data and should be finished after a minute...

Page 15: ...eams with the same content on different ports one full size and one scaled down When the image size is set to values smaller than half the linear sensor pixel number see data sheet below binning is en...

Page 16: ...anging the exposure time For values 0 exposure time is limited to multiples of the value Exposure values in between are realized by changing the gain For 50Hz lighting flicker free exposure is realize...

Page 17: ...eters can be set At the moment camera settings can only be changed by the web interface It is possible to change the exposure time the gain of the different color channels image flipping and Bayer mod...

Page 18: ...mounting position of the camera Changes Bayer mode which is fixed yet See below Bayer mode because the flipping will change the starting pixels the Bayer mode the mode has to be adjusted if flipping...

Page 19: ...d DHCP mode For static IP fill out the fields as needed And press Save data To use the new settings pressing Restart network is needed For DHCP mode no addresses are needed they are obtained from the...

Page 20: ...20 4 4 Menu general appearance This image shows the general menu structure 4 5 About Menu The About screen shows data needed for service enquiries or for searching a camera in the network...

Page 21: ...21 5 Appendix Data sheet key data Below you find the key data for the sensor...

Reviews: