Adjusting the switching point via the teach input

The switching point of the sensor is set to 300mm or 1200mm on delivery. 

By means of a simple teach event, the switching points can be individually taught to an arbitrary distance within the scanning 
range with 1-point teach (static) or 2-point window-teach (static). The Leuze 

PA1/XTSX-M12

 Teach Adapter can be used for this 

purpose. The adapter can also be used to easily switch the output function from NO contact to NC contact.

1-point teach (static)

2-point window-teach (static)

1. Place

 object at desired switching distance.

1.

First, 

place

 object at desired switching distance for 

switching point 1

.

2.

To adjust output 

OUT1

connect

 the 

Teach-IN

 input to 

U

B

 for 

2 … 7s

 

(Leuze Teach Adapter: position "Teach-U

B

"). 

The current state of output 

OUT1

 is frozen while the adjustment is made.

2.

To adjust output 

OUT1

connect

 the 

Teach-IN

 input to 

U

B

 for 

7 … 12s

 

(Leuze Teach Adapter: position "Teach-U

B

") until the 

yellow and green 

LEDs flash alternately at 3Hz

.

3.

The 

yellow LED flashes at 3Hz

 and is then 

ON

The current object distance has been taught as the new switching point. 

3. Release the button

. The sensor remains in teach mode and the LEDs 

continue to flash. 

4.

Error-free teach: 

LED

 states and switching behavior according to the dia-

gram shown above. 

Faulty teach

 (object may be too close or too far away – please note scan-

ning range)

green and yellow LEDs flash at 8Hz

 until an error-free teach event is 

performed.
The output 

OUT1

 is inactive as long as there is a teaching error.

4.

Then, 

place

 the object at the desired switching distance for 

switching 

point 2

Note

:

The 

minimum distance between the switching points

 is as follows: 

scanning range of 400mm:

40mm

scanning range of 1200mm:

120mm

5.

To complete the teach event, briefly 

connect

 the 

Teach-IN

 input to 

U

B

 

again (Leuze Teach Adapter: position "Teach-U

B

"). 

The switching window was taught in. 

6.

Error-free teach: LED states and switching behavior according to the 
diagram shown above. 

Faulty teach 

(object may be too close or too far away – please note scan-

ning range)

green and yellow LEDs flash at 8Hz

 until an error-free teach event is 

performed.

HTU318

Ultrasonic sensors with 1 switching output