Leuze electronic HTU318-300 M12 Series Quick Start Manual Download Page 2

HTU318-300…-M12 - 01

2017/02

HTU318-1200…-M12 - 01

Technical data

Ultrasonic specifications

HTU318-300/…-M12

HTU318-1200/…-M12

Scanning range 

1)

1) At 20°C

40 … 300mm 

2)

 

2) Target: 100mm x 100mm plate

80 … 1200mm 

2)

 

Adjustment range

40 … 300mm

80 … 1200mm

Ultrasonic frequency

300kHz

200kHz

Typ. opening angle

7° ± 2°

8° ± 2°

Resolution

< 2mm

< 2mm

Direction of beam

Axial

Axial

Reproducibility

± 0.5% 

1)

 

3)

3) From end value

± 0.5% 

1) 3)

Switching hysteresis

1% 

3)

 1% 

3)

 

Temperature drift

5% 

4)

4) Over the temperature range -20°C … +70°C

5% 

4)

 

Timing

Switching frequency

8Hz

5Hz

Response time

62ms

100ms

Readiness delay 

< 100ms

< 100ms

Electrical data

Operating voltage U

5)

 

5) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC

10 … 30V DC (incl. ± 5% residual ripple) 

Residual ripple

±

5% of U

B

Open-circuit current

35mA

Switching output

…/4…
…/2…

1 PNP transistor switching output 
1 NPN transistor switching output

Function

NO (normally open), preset

Output current

Max. 150mA

Switching range adjustment

1-point teach: teach-in (pin 2) 2 … 7s to U

B

2-point teach: teach-in (pin 2) 7 … 12s to U

B

 

Changeover 
NO/NC

Teach-in (pin 2) > 12s to U

B

 

Indicators

Yellow LED 

OUT1: object detected

Yellow LED, flashing

Teach-in

Green and yellow LEDs flashing

Teaching error

Green LED 

Object within the scanning range

Mechanical data 

Housing Plastic 

(PBT)

Active surface

Epoxy resin, glass fiber reinforced

Weight 65g

Ultrasonic transducer

Piezoceramic 

6)

6) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT)

Connection type 

M12 connector, 4-pin

Fitting position

Any

Environmental data

Ambient temp. (operation/storage) -20° … +70°C/-20° … +70°C 
Protective circuit 

7)

7) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection

1, 2, 3

VDE protection class

III

Degree of protection 

IP 67

Standards applied

EN 60947-5-2

Certifications

UL 508, CSA C22.2 No.14-13 

5)

 

8)

 

8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min, 

in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)

Diagrams

HTU318-300/…-M12

HTU318-1200/…-M12

Notes

Observe intended use!

This product is not a safety sensor 
and is not intended as personnel 
protection.

The product may only be put into 
operation by competent persons.

Only use the product in accor-
dance with its intended use.

-100

-50

0

50

100

0

50

100 150 200 250 300 350

y1

y2

Object distance x [mm]

Width

 y of th

e s

ound

 co

ne [mm

]

Typ. response behavior (plate 100x100mm)

-100

-50

0

50

100

0

50

100 150 200 250 300 350

y1

y2

Object distance x [mm]

W

idth y

 of the

 so

und

 co

ne [mm]

Typ. response behavior (rod Ø 25mm)

-200

-100

0

100

200

0

200 400 600 800

1400

1200

1000

y1

y2

Object distance x [mm]

Wi

dth y

 of the s

ou

nd c

one

 [mm]

Typ. response behavior (plate 100x100mm)

-200

-100

0

100

200

0

200 400 600 800

1400

1200

1000

y1

y2

Object distance x [mm]

Wid

th y o

f the s

ou

nd c

one

 [mm]

Typ. response behavior (rod Ø 25mm)

Object distance [mm]

Target (fixed):

plate or rod

Sound cone

= f (

α

,x)

HTU318

Reviews: