FE
Connect the M12 housing/cable shield to the functional earth via the
RSL housing
NOTICE
Pins 2 and 3 of the X2 plug must not be contacted.
Technical data of the MELD signal output
The MELD signal output can be accessed via the switching contact and is electri-
cally isolated through a relay.
Output contact
1 NO contact
Switching capacity of the contact acc. to
EN/IEC 60947-5-1
DC13: 24 V / 100 mA
1x10
5
switching cycles
Max. contact voltage
U
max
<= 30 V
Permissible contact current
0.5 mA <= I
max
<= 100 mA
Ext. contact fuse protection
1 A delay-action
Max. switching frequency
0.5 Hz
Mechanical life time
50x10
6
switching cycles
Pickup delay
5 ms
Regression delay
5 ms
Pin assignments and core colors in combination with M12 standard cable
Pin No. Core color
(CB-M12-xx000E-4GF)
1
Brown
2
White
3
Blue
4
Black
FE
Shield
14
EN