Diagnostics and troubleshooting
Leuze electronic
BPS 307i
71
10
Diagnostics and troubleshooting
10.1 What to do in case of failure?
After switching on the BPS, display elements (see chapter 3.3) assist in checking the proper function and
troubleshooting.
In case of error, you can determine the error from the LED displays. With the error message you can deter
-
mine the cause of the error and initiate measures to rectify it.
Switch off the system and leave it switched off.
Analyze the cause of the error using the operation indicators, the error messages and the diagnostic
tools (also with the help of the webConfig tool,
DIAGNOSTICS
tab) and rectify the error.
10.1.1 Diagnostics with webConfig tool
System events are displayed in the webConfig tool via the
DIAGNOSTICS
tab. Noteworthy system events
are recorded in the event log. Depending on their importance, the events are classified as info, warning,
error and critical error. The statistics counters detect the number of all recorded as well as non-acknowl
-
edged messages. With the message filters, the events can be filtered according to their status and their
class.
Figure 10.1:
DIAGNOSTICS
webConfig function
10.2 Operating indicators of the LEDs
You can ascertain general causes of errors via the PWR and BUS status LEDs (see table 10.4).
NOTICE
Contact Leuze electronic subsidiary/customer service.
If you are unable to rectify a fault, contact the Leuze electronic branch responsible for you or call the
Leuze electronic customer service (see chapter 12 "Service and support").