BCL 338i in the EtherCAT system
Leuze electronic
BCL 338
i
151
TNT
35/7-2
4
V
Standby
This control bit activates the standby function of the bar code reader.
0
Standby off
1
Standby on
Note!
During a data reset (see object 0x2200
h
sub-index 05
h
), the status data of this object is
not
deleted
11.5
Communication examples
11.5.1
Application case: Reading a bar code
Read and transmit two bar codes in fragmented mode.
Object configuration:
Object 0x2200
h
Activation, mode = 1 handshake operation (with ACK)
Object 0x2300
h
Fragmented result, fragment length = 4
Object 0x2000
h
Result data, 16 bytes data length