Commi
ss
ionin
g
and confi
g
uration
Le
u
ze electronic
BCL
3
04
i
1
3
5
TNT
35/7-2
4
V
10.11.3 Module 63 – Ali
g
nment
Description
The mod
u
le define
s
inp
u
t
a
nd o
u
tp
u
t d
a
t
a
for the
a
lignment mode of the BCL
3
04
i
. The
a
lignment mode i
s
us
ed for e
as
y
a
lignment of the BCL
3
04
i
with the
ba
r code. U
s
ing the
tr
a
n
s
mitted decoding q
ua
lity
as
a
percent
a
ge, the optim
u
m
a
lignment c
a
n
b
e e
as
ily
s
elected. Thi
s
mod
u
le
s
ho
u
ld not
b
e
us
ed in connection with mod
u
le
8
1 (A
u
toReflAct)
as
thi
s
m
a
y c
aus
e m
a
lf
u
nction
s
.
Parameter
None
Input data
Input data length
1
b
yte
Output data
Output data length
1
b
yte
Input data
De
s
cription
Addr.
Data type
Value ran
g
e
Init
value
Unit
Decoding q
ua
lity
Tr
a
n
s
mit
s
the c
u
rrent decoding q
ua
lity
of the
ba
r code loc
a
ted in the
s
c
a
nning
b
e
a
m
0
Byte
0 … 100
0
Percent-
a
ge
T
ab
le 10.41:
Inp
u
t d
a
t
a
for mod
u
le 6
3
Output data
De
s
cription
Addr.
Data type
Value ran
g
e
Init
value
Unit
Alignment mode
S
ign
a
l
a
ctiv
a
te
s
a
nd de
a
ctiv
a
te
s
the
a
lignment mode for optim
u
m
a
lignment of the BCL
3
04
i
with
the
ba
r code
0.0
Bit
0 -> 1: On
1 -> 0: Off
0
-
T
ab
le 10.42:
O
u
tp
u
t d
a
t
a
for mod
u
le 6
3