Online commands
Leuze
electronic
72
BCL 21/22
Leuze electronic
Deactivate sensor input 2
Activate switching output
Deactivate switching output
11.1.3
’Online’ Commands for System Checking
Query: Supply Voltage
Command
’.’
Description
The command deactivates the definition of reference code 1.
Parameter
no
Acknowledge-
ment
no
Command
’OA’
Description
The command activates a selected switching output.
Parameter
’OAx’
: Activate switching output
x
: Switching output No.
’1’
(output 1)
’2’
(output 2)
Acknowledge-
ment
no
Command
’OD’
Description
The command deactivates a selected switching output.
Parameter
’ODx’
: Deactivate switching output
x
: Switching output No.:
’1’
(output 1)
’2’
(output 2)
Acknowledge-
ment
no
Command
’DUV’
Description
Queries the supply voltage with which the bar code reader is supplied.
Parameter
no
Acknowledge-
ment
’DUVxx.x’
xx.x
:
Voltage value, for example 28.2 for 28.2Volt.