Commissioning
Leuze electronic
BCL 21/22
47
TNT 35/7-24V
7
Commissioning
Attention Laser Radiation!
Follow the safety notices in chapter 2.3 on page 7!
7.1
Measures to be performed prior to the initial commissioning
!
Before commissioning, familiarise yourself with the operation and configuration of the
device(s)!
!
Before switching on, recheck all connections and ensure that they have been properly
made.
Configuration elements using the example of the MA 2
Figure 7.1:
Configuration elements in the MA 2
Setting the device address
The device address is set in the MA 2/MA 4… using a rotary code switch. The setting is
carried out as follows:
!
Set the device address to
• 0, if the combined BCL 21 / MA 2/MA 4… unit will not be operated in a network,
• 1…30, if several BCL 21 / MA 2/MA 4… units will be operated in a network. Each
multiNet plus network device must have a different device address assigned to it. If
the MA 2/MA 4… is connected to the multiNet Master, the device combination BCL 21
with MA 2/MA 4… automatically turns into a multiNet plus slave device.
Notice!
Address 31 is used for resetting the parameters.
Coding switch 0 … F
for setting the
device address
switch positions 0 … F
correspond
to the device address
0 … 15 or 16 … 31
Operating mode switch:
Switch in upper pos.:
operation
Switch in lower pos.:
service
Jumper for setting the
device address range:
Jumper above:
addr. 0 … 15
Jumper below:
addr. 16 … 31