2016/12
Technical data
Optical data
Throughbeam
principle
Scanning principle
Operating range/scanning range
1)
1) Range/scanning range depending on the fiber optics used
Up to 5000mm
Up to 1350mm
Light source
LED (modulated light)
Wavelength
LV463.XR…
LV463I.XR…
660nm (visible red light)
880nm (infrared light)
Timing
Readiness delay
≤
500ms
Internal cycle time
100μs
Signal range
Extra Long Range
(XLR)
Long Range
(LR)
Standard
(STD)
Speed
(S)
High Speed
(HS)
Response time
24ms
8ms
2ms
1000μs
500μs
Switching frequency
2)
2) With a duty cycle of 1:1
21Hz
62.5Hz
250Hz
500Hz
1000Hz
Display area (digits)
0 … 9999
0 … 9999
0 … 9999
0 … 9999
0 … 9999
Repeatability
180μs
180μs
180μs
150μs
100μs
Increased protection against optical
crosstalk
Yes
Yes
Yes
Yes
No
Increased protection against ambient
light through energy-saving lamps
Yes
Yes
Yes
No
No
Electrical data
Operating voltage U
B
3)
3) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
12 … 24VDC ± 10%
Residual ripple
≤
10% of U
B
Open-circuit current
≤
40mA @ 24VDC
Switching output
See part number code
Switching output time functions
Switch-on/-off delay,
passing contact (on actuation or fall-back),
(combinations are limited
Combinations of timing functions
)
Adjustable times (time functions)
0 … 9999ms
Signal voltage high/low
≥
(U
B
-2.5V)/
≤
2.5V
Output current
≤
100mA
Switching threshold
Adjustable using the teach function or
+
/
-
buttons
Indicators
Yellow LEDs
1/2 switching output active
Display
2 x 7-segment LED, 4-digit,
Red:
signal strength,
Green:
switching threshold
Mechanical data
Housing
ABS/PC black/red, transparent PC cover
Weight
63g with 2000mm cable
70g with 150mm cable and M12 connector
Connection type
Cable 2000mm, 5 x 0.25mm
2
, or
Cable 150mm with M12 connector, 5-pin
Fiber optic connection
Clamp-mounting, 2 x Ø 2.2mm
Environmental data
Ambient temp. (operation/storage)
-10°C … +55°C/-20°C … +85°C
Protective circuit
4)
4) 2=polarity reversal protection, 3=short circuit protection for all outputs
2, 3
Degree of protection
IP 50, NEMA 1
Standards applied
EN 60947-5-2
Certifications
UL 508, C22.2 No.14-13
3)
5)
5) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.24A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
Additional functions
Sensor adjustment
Menu-driven using display and rocker push button
Notes
Explanation of the
signal ranges
Extra Long Range (XLR)
:
Extra long operating range,
longest response time,
display area 0 … 9999
Long Range (LR)
:
Long operating range with
good response time;
display area: 0 … 9999
Standard (STD):
Medium operating range and
medium response time;
display area: 0 … 9999
Speed (S)
:
Short operating range and
short response time;
display area: 0 … 9999
High Speed (HS)
:
Short operating range,
very short response time;
display area: 0 … 9999
NOTE
Detailed specifications on the range/
scanning range are enclosed in the
data sheets of our fiber optics type
KF
,
KFX
or
GF
.
Observe intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with its intended use.
LV463.XR