Combining timing functions

Timing functions can only be combined to a limited extent. Impermissible combinations are suppressed from the subfunctions menu. 
Here is an overview of the permissible combinations (•):

Operating mode ADJ - teaching the switching outputs 
(CH1/CH2)

Switching outputs OUT1 and OUT2 can be taught individually. Set the selector switch for the channel 
to the desired position 

CH1

 (switching output OUT1) or 

CH2

 (switching output OUT2). 

Set the selector switch for the operating mode to the 

ADJ

 position. 

Depending on the setting of the 

Select teach mode

 subfunction (

tch

 

SEL1 

tch

 

SEL2

), one of the following teach modes appears:

Static 1-point teach

Static 2-point teach

Dynamic teach

Teach process

Tip!

For reliable function, the difference between the signal value while an object is present and the signal value with no object should be at 
least 10 … 20%. In general: the larger the difference, the more reliable the detection.

OFF

 

dLY

 

Switch-off 
delay

OFF

 

ISho

Passing contact 
OFF

On

 

dLY

 

Switch-on 
delay

On

 

ISho

 

Passing contact 
ON

OFF

 

dLY

 

Switch-off 
delay

OFF

 

ISho

Passing contact 
OFF

On

 

dLY

 

Switch-on 
delay

On

 

ISho

 

Passing contact 
ON

Step

Static 1-point teach

Static 2-point teach

Dynamic teach

Œ

 

Place object in light beam.
The red display shows the signal value, the green 
display the current switching threshold.

Place object in light beam.
The red display shows the signal value, the green 
display the current switching threshold.

Press the rocker push button. The green display 
shows 

dYn

, the red display the current signal 

value. 
The amplifier now scans signal values for approx. 1 
minute.



 

Press the rocker push button; the teach value is 
accepted.

Press the rocker push button, 

first

 teach value is 

accepted.

Move several objects through the light beam; to 
end the event, press the rocker push button again.
After the scanning time elapses, the teach event 
ends automatically.

Ž

 

Following a successful teach, 

PASS

 appears on 

the green display and the signal value is displayed 
as the new switching threshold. 
In the event of a faulty teach, 

FAIL

 appears on the 

red display. In this case, the signal value may be 
too small and cannot be accepted as a teach value 
(

 

Table with minimum teach values as a func-

tion of the setting

). 

Check object and/or placement and repeat event.

2nd

 appears on the green display; the red display 

shows the current signal value.
Place object 2 or object at distance 2 and press the 
rocker push button 

within one minute

. The 

sec-

ond

 teach value is accepted. 

If the rocker push button is not pressed within one 
minute, the teach event is interrupted and the pre-
vious switching threshold is retained.
Following a successful teach, 

PASS

 appears on 

the green display. The new switching threshold 
now lies approximately midway between the two 
taught signal values. 
In the event of a faulty teach, 

FAIL

 appears on the 

red display. In this case, the minimum distance 
between the two teach points may be too small (

 

Table with minimum teach values as a function 
of the setting

). 

Try to set a larger distance between the two signal 
values and repeat the event.

Following a successful teach, 

PASS

 appears on 

the green display. The new switching threshold 
now lies between the maximum and the minimum 
of the scanned signal values. 
In the event of a faulty teach, 

FAIL

 appears on the 

red display. In this case, the minimum distance 
between the scanned signal values may be too 
small (

 

Table with minimum teach values as a 

function of the setting

). 

Try to set a larger distance between the signal val-
ues and repeat the event.



 

The switching threshold can be freely increased or 
decreased at a later time by rocking the rocker 
push button to the left (

+

) and right (

-

). 

The change is accepted if both displays flash 
briefly several times. 

The switching threshold can be freely increased or 
decreased at a later time by rocking the rocker 
push button to the left (

+

) and right (

-

). 

The change is accepted if both displays flash 
briefly several times. 

The switching threshold can be freely increased or 
decreased at a later time by rocking the rocker 
push button to the left (

+

) and right (

-

). 

The change is accepted if both displays flash 
briefly several times. 

LV463.XR

Summary of Contents for 50133980

Page 1: ...puts Connection via cable or cable with M12 connector Up to 5000mm Up to 1350mm 10 30 V DC Accessories available separately Plastic fiber optics KF KFX Glass fiber optics GF Ready made cables KD Mounting device BTU LV463 IEC 60947 IEC 60947 Dimensioned drawing A Clamping lever for fiber optic cable unlock in direction of arrow B Connection for fiber optics receiver C Connection for fiber optics tr...

Page 2: ... LED 4 digit Red signal strength Green switching threshold Mechanical data Housing ABS PC black red transparent PC cover Weight 63g with 2000mm cable 70g with 150mm cable and M12 connector Connection type Cable 2000mm 5 x 0 25mm2 or Cable 150mm with M12 connector 5 pin Fiber optic connection Clamp mounting 2 x Ø 2 2mm Environmental data Ambient temp operation storage 10 C 55 C 20 C 85 C Protective...

Page 3: ...activation or multiplex operation Pin assignment of connector pin 5 gray cable wire OUT2 4 PNP transistor switching output light switching 2 NPN transistor switching output light switching Connection technology Not specified Connection cable standard length 2000mm 4 5 wire 1 1 Devices with 1 x OUT and multifunction input 4 wire or 4 pin Devices with 2 x OUT and multifunction input 5 wire or 5 pin ...

Page 4: ...nts DIN rail TS 35 35mm x 7 5mm DIN rail TS 35 35mm x 7 5mm Spring mounted DIN rail mount The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage Alternatively the amplifier can also be mounted without a DIN rail using the mounting accessory and M3 screws Channel changeover slide switch Channel 1 CH1 Switching output 1 Channel 2 CH2 Switching output 2 Lever for fiber ...

Page 5: ...In the ADJ operating mode the switching threshold can be increased or decreased by rocking In the PRG operating mode rock to navigate in the menu Button Press the rocker push button in the middle position to accept a setting made in the PRG operating mode Indicator Signal strength In the RUN and ADJ operating modes the display shows the current signal value In the PRG operating mode information on...

Page 6: ...tion Possible settings value range Factory setting default Explanation out SEL1 Switching function OUT1 out SEL2 Switching function OUT2 Lon don Lon Individual setting for CH1 and CH2 depending on switch position Lon Switching output light switching If throughbeam fiber optics are installed the switching output is active when the light path is free If a scanning system is installed the switching o...

Page 7: ...ed display the signal values are constantly displayed At the end of the teach event the switching threshold is cal culated at approximately midway between the smallest and largest sig nal value Auto thr Threshold tracking Tracking the switching threshold oFF aus On ein oFF Individual setting for CH1 and CH2 depending on switch position The function is only available during dynamic teaching If the ...

Page 8: ...A n number Defines that this unit functions as a master and a total of n sensors were wired in parallel Value range n 2 6 Example mA 4means unit is the master a total of 4 sensors are wired to one another via the multi funct multifunction input Setting for slaves SL n number Defines that this unit functions as a slave and has indi vidual address n Value range address n 1 5 Example SL 3 means unit ...

Page 9: ...Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Rising edge Falling edge Active state of the switching output Set delay ti...

Page 10: ...l value is displayed as the new switching threshold In the event of a faulty teach FAIL appears on the red display In this case the signal value may be too small and cannot be accepted as a teach value Table with minimum teach values as a func tion of the setting Check object and or placement and repeat event 2nd appears on the green display the red display shows the current signal value Place obj...

Page 11: ...signal is applied prior to the teach Action begins with the rising edge tTeach 20 80ms Operating mode selector switch locked The teach event begins with the fall ing edge 1 Static 1 point teach The current signal value is taken over as the teach value with the falling edge 2 Static 2 point teach The current signal value is taken over as teach value 1 with the falling edge 3 Dynamic teach The senso...

Page 12: ...1s Teach mode OUT1 1 point teach T P T T T T T P T 2 point teach T P T T T T T P T T T Dynamic teach T P T T T T T P T T T T T Switching function OUT1 Light switching T P T T T T T T T P T Dark switching T P T T T T T T T P T T T Teach mode OUT2 1 point teach T P T P T 2 point teach T P T P T T T Dynamic teach T P T P T T T T T Switching function OUT2 Light switching T P T T T P T Dark switching T...

Page 13: ...unct multifunction inputs pin 2 ws WH are connected in parallel For settings see subfunctions Maximum 6 minimum 2 units 1 x master 1 5 slaves Each unit can be either a master mA or slave SL The master also requires the information on the number of units connected in parallel n 1 number of slaves Each slave also receives an individual address 1 5 max The master generates a timing signal on pin 2 or...

Page 14: ...n identical address from 1 5 Result Master and slaves have a time offset of 1 5 ms slaves with the same address operate synchronously Model 2 Synchronous operation through an external activation signal at the multi funct input pin 2 ws WH Subfunction setting Function InP SEL multi funct input SYnc PLc activation input multi funct activation input pin 2 ws WH Transmitter OFF Transmitter OFF Transmi...

Reviews: