Extra large operating ranges

Two, large, easy-to-read displays for the 
simultaneous display of the signal value 
and the switching threshold

Simple operation and easy-to-understand
menu functions for optimum configuration

Internal multiplex operation of up to six 
units 

Line teach or external transmitter activation  

Three different teach modes for fast sensor 
adjustment

2 switching outputs (PNP or NPN)

One indicator diode for each of the two 
outputs 

Connection via cable or cable with M12 
connector

Up to 
5000mm

Up to 
1350mm

10 - 30 V

DC

Accessories:

(available separately)

Plastic fiber optics (KF, KFX)

Glass fiber optics (GF)

Ready-made cables (KD …)

Mounting device (BTU LV463)

IEC 60947...

IEC 60947...

Dimensioned drawing

A

Clamping lever for fiber optic cable (unlock in direction of arrow)

B

Connection for fiber optics receiver

C

Connection for fiber optics transmitter

35

10

Mounting accessories

With M8 connector

With cable

BTU LV463

 

Part no. 50120869

Electrical connection

5-pin connector

5-wire cable

multi funct

:

-  OFF
- Line teach
- Activation input
- Multiplex operation

Details 

 

Description of the subfunctions

NOTE

: Open lead wires must be connected to a terminal box.

LV463.XR

Long Range amplifier with 2 switching outputs for fiber optics

   LV463.XR 2SWO - 02

en

02

-2

01

6/

12

5

0

1

353

47

Summary of Contents for 50133980

Page 1: ...puts Connection via cable or cable with M12 connector Up to 5000mm Up to 1350mm 10 30 V DC Accessories available separately Plastic fiber optics KF KFX Glass fiber optics GF Ready made cables KD Mounting device BTU LV463 IEC 60947 IEC 60947 Dimensioned drawing A Clamping lever for fiber optic cable unlock in direction of arrow B Connection for fiber optics receiver C Connection for fiber optics tr...

Page 2: ... LED 4 digit Red signal strength Green switching threshold Mechanical data Housing ABS PC black red transparent PC cover Weight 63g with 2000mm cable 70g with 150mm cable and M12 connector Connection type Cable 2000mm 5 x 0 25mm2 or Cable 150mm with M12 connector 5 pin Fiber optic connection Clamp mounting 2 x Ø 2 2mm Environmental data Ambient temp operation storage 10 C 55 C 20 C 85 C Protective...

Page 3: ...activation or multiplex operation Pin assignment of connector pin 5 gray cable wire OUT2 4 PNP transistor switching output light switching 2 NPN transistor switching output light switching Connection technology Not specified Connection cable standard length 2000mm 4 5 wire 1 1 Devices with 1 x OUT and multifunction input 4 wire or 4 pin Devices with 2 x OUT and multifunction input 5 wire or 5 pin ...

Page 4: ...nts DIN rail TS 35 35mm x 7 5mm DIN rail TS 35 35mm x 7 5mm Spring mounted DIN rail mount The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage Alternatively the amplifier can also be mounted without a DIN rail using the mounting accessory and M3 screws Channel changeover slide switch Channel 1 CH1 Switching output 1 Channel 2 CH2 Switching output 2 Lever for fiber ...

Page 5: ...In the ADJ operating mode the switching threshold can be increased or decreased by rocking In the PRG operating mode rock to navigate in the menu Button Press the rocker push button in the middle position to accept a setting made in the PRG operating mode Indicator Signal strength In the RUN and ADJ operating modes the display shows the current signal value In the PRG operating mode information on...

Page 6: ...tion Possible settings value range Factory setting default Explanation out SEL1 Switching function OUT1 out SEL2 Switching function OUT2 Lon don Lon Individual setting for CH1 and CH2 depending on switch position Lon Switching output light switching If throughbeam fiber optics are installed the switching output is active when the light path is free If a scanning system is installed the switching o...

Page 7: ...ed display the signal values are constantly displayed At the end of the teach event the switching threshold is cal culated at approximately midway between the smallest and largest sig nal value Auto thr Threshold tracking Tracking the switching threshold oFF aus On ein oFF Individual setting for CH1 and CH2 depending on switch position The function is only available during dynamic teaching If the ...

Page 8: ...A n number Defines that this unit functions as a master and a total of n sensors were wired in parallel Value range n 2 6 Example mA 4means unit is the master a total of 4 sensors are wired to one another via the multi funct multifunction input Setting for slaves SL n number Defines that this unit functions as a slave and has indi vidual address n Value range address n 1 5 Example SL 3 means unit ...

Page 9: ...Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Rising edge Falling edge Active state of the switching output Set delay ti...

Page 10: ...l value is displayed as the new switching threshold In the event of a faulty teach FAIL appears on the red display In this case the signal value may be too small and cannot be accepted as a teach value Table with minimum teach values as a func tion of the setting Check object and or placement and repeat event 2nd appears on the green display the red display shows the current signal value Place obj...

Page 11: ...signal is applied prior to the teach Action begins with the rising edge tTeach 20 80ms Operating mode selector switch locked The teach event begins with the fall ing edge 1 Static 1 point teach The current signal value is taken over as the teach value with the falling edge 2 Static 2 point teach The current signal value is taken over as teach value 1 with the falling edge 3 Dynamic teach The senso...

Page 12: ...1s Teach mode OUT1 1 point teach T P T T T T T P T 2 point teach T P T T T T T P T T T Dynamic teach T P T T T T T P T T T T T Switching function OUT1 Light switching T P T T T T T T T P T Dark switching T P T T T T T T T P T T T Teach mode OUT2 1 point teach T P T P T 2 point teach T P T P T T T Dynamic teach T P T P T T T T T Switching function OUT2 Light switching T P T T T P T Dark switching T...

Page 13: ...unct multifunction inputs pin 2 ws WH are connected in parallel For settings see subfunctions Maximum 6 minimum 2 units 1 x master 1 5 slaves Each unit can be either a master mA or slave SL The master also requires the information on the number of units connected in parallel n 1 number of slaves Each slave also receives an individual address 1 5 max The master generates a timing signal on pin 2 or...

Page 14: ...n identical address from 1 5 Result Master and slaves have a time offset of 1 5 ms slaves with the same address operate synchronously Model 2 Synchronous operation through an external activation signal at the multi funct input pin 2 ws WH Subfunction setting Function InP SEL multi funct input SYnc PLc activation input multi funct activation input pin 2 ws WH Transmitter OFF Transmitter OFF Transmi...

Reviews: