5.2 IT 1911i to MA 200i
RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, suffix CR/LF.
Required parts:
1x
50122434
IT 1911i ER-3
1x
50122431
Base station IT 1911i
1x
50114517
KB 232-1 IT 190x
1x
50123862
Power supply unit
1x
50113397
KB JST-HS-300
1x
50112893
MA 204i
Profibus gateway
or
50112892
MA 208i
Ethernet gateway
or
50112891
MA 248i
Profinet gateway
5.2.1
Commissioning
•
Open the MA 200i
•
Guide KB JST-HS-300 with the PG cable gland through the threaded hole and insert
the 12-pin JST connector
•
Connect the base station with the RS 232 cable
•
Connect the RS 232 cable to the 9-pin D-sub connector
•
Set the address using the address switch
•
Insert the field bus connection cable
•
Apply the voltage supply.
Please connect the base station acc. to the following figure.
Leuze electronic
IT1911i