Summit Series ® 

10 of 20 

User’s Manual 

 

CAUTION:    TO  REDUCE  THE  RISK  OF  ELECTRIC  SHOCK  OR  FIRE,  DISCONNECT  AC  POWER 

FROM THE CHARGER BEFORE INSTALLING OR REMOVING UNIT. 

DANGER:    NEVER  ALTER  THE  AC  POWER  CORD  OR  PLUG  PROVIDED.    IF  IT  WILL  NOT  FIT  AN 

OUTLET,  OBTAIN  THE  CORRECT  CHARGER  IEC  AC  CORDSET  FOR  THE  OUTLET,  OR  HAVE  A 
PROPER  OUTLET  INSTALLED  BY  A  QUALIFIED  ELECTRICIAN.    IMPROPER  CONNECTION  CAN 
RESULT IN A RISK OF ELECTRIC SHOCK. 

 
If  an  extension  cord  is  necessary,  it  must  be  a  3-conductor,  No.  12  AWG  minimum,  heavy-duty  cord  with 
ground.    It  must  also  be  in  good  electrical  condition  and  as  short  as  possible,  50  ft  (15m)  maximum.    Make 
sure that the pins on the plug of the extension cord are the same number, size, and shape as the AC power 
cord  plug  on  the  charger.    The  use  of  an  improper  extension  cord  could  result  in  a  risk  of  fire  or  electrical 
shock. 
 
Locate all cords so that they will not be stepped on, tripped over, or otherwise subjected to damage, stress, or 
accidentally disconnected. 
 

CAUTION:    VERIFY  THAT  THE  AC  POWER  CORD  IS  FULLY  ENGAGED  IN  THE  IEC  INLET  AND 

CANNOT BE PULLED LOOSE BEFORE USING THE CHARGER. 
 

DANGER:    RISK  OF  ELECTRIC  SHOCK!    CONNECT  THE  AC  SUPPLY  CORD  DIRECTLY  TO  A 

GROUNDED, 3-WIRE OUTLET.  DO NOT TOUCH UNINSULATED PORTION OF DC OUTPUT TERMINALS 
OR BATTERY TERMINALS.  REPLACE DEFECTIVE CORDS, WIRES, OR CONNECTORS IMMEDIATELY. 

 

6  DC OUTPUT 

 

WARNING:    LEAD-ACID  BATTERIES  GENERATE  EXPLOSIVE  GAS.    CHARGE  ONLY  IN  WELL 

VENTILATED AREAS.  TO PREVENT ARCING OR BURNING NEAR BATTERIES, DO NOT DISCONNECT 
THE  DC  CHARGING  CONNECTOR(S)  FROM  THE  BATTERIES  WHEN  THE  CHARGER  IS  OPERATING.  
IF  THE  CHARGE  CYCLE  MUST  BE  INTERRUPTED,  UNPLUG  THE  AC  POWER  CORD  BEFORE 
DISCONNECTING THE DC OUTPUT CONNECTOR(S) FROM THE BATTERIES. KEEP SPARKS, FLAME, 
AND SMOKING MATERIALS AWAY FROM BATTERIES.  TO REDUCE THE RISK OF FIRE, DO NOT USE 
THE CHARGER NEAR FLAMMABLE MATERIALS OR VAPORS. 
 

Only  charge  batteries  of  the  same  type,  voltage,  number  of  cells,  and  amp-hour  capacities  listed  on  the 
charger ratings label. 

 

The  DC  output  cordset  includes  a  commonly-used  connector/plug.    The  polarity  of  the  charger  DC 
connector/plug must be the same as the battery connector.  The BLACK DC cable must be connected to the 
battery  negative  (-),  and  the  WHITE  or  RED  DC  cable  must  be  connected  to  the  battery  positive  (+).  The 
charger will not operate if the polarity is reversed. 
 

7  VEHICLE LOCKOUT CONTROL (OPTIONAL) 

 
The  charger  may  be  configured  with  an  optional  lockout/interlock  control  signal  to  prevent  vehicle/equipment 
operation  while  the  charger  is  in  use.    If  the  charger  was  factory-configured  for  on-board  use,  the  lockout 
control signal will be active while AC power is applied to the charger.  If the charger was factory-configured for 
off-board use, the lockout control signal will be active while a valid battery is connected to the charger. 
 
The lockout control wire will be pulled down to battery negative (-) when active.  Two (2) lockout control options 
exist.  If you are uncertain of which one your charger includes, please contact your dealer. 
 

Option #1 

Summary of Contents for SUMMIT 27940

Page 1: ...SWITCH MODE INDUSTRIAL BATTERY CHARGER USER S MANUAL Important Safety Installation Operation and Maintenance Instructions www LesterElectrical com ...

Page 2: ...r for future reference Document any configuration or settings changes that are made by marking the ratings label on your charger or on an additional label or tag attached to your charger This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter...

Page 3: ...9 4 1 Off Board Chargers 9 4 2 On Board Chargers 9 5 AC INPUT 9 6 DC OUTPUT 10 7 VEHICLE LOCKOUT CONTROL OPTIONAL 10 8 BATTERY TEMPERATURE SENSOR OPTIONAL 11 9 PROPER CARE OF DEEP CYCLE LEAD ACID MOTIVE POWER BATTERIES 11 9 1 Personal Safety Precautions 12 10 CHARGER OPERATION 12 10 1 Off Board Charger Operation 13 10 2 On Board Charger Operation 14 10 3 Storage Mode Operation 14 11 LED INDICATORS...

Page 4: ...CH UNINSULATED PORTION OF AC OR DC CONNECTORS OR UNINSULATED BATTERY TERMINAL 8 DANGER RISQUE DE CHOCKS ÉLECTRIQUES NE PAS TOUCHER LES PARTIES NON ISOLÉES DU CONNECTEUR DE SORTI OU LES BORNES NON ISOLÉES DE L ACCUMULATEUR 9 CAUTION CHARGE ONLY BATTERIES OF THE SAME TYPE VOLTAGE CELL NUMBER AND AMP HOUR CAPACITIES AS SHOWN ON THE LABEL OTHER TYPES OF BATTERIES MAY BURST CAUSING PERSONAL INJURY AND ...

Page 5: ...CH MAY CAUSE BURNS DO NOT GET ACID IN EYES ON SKIN OR CLOTHING IF CONTACT WITH THE EYES OCCURS FLUSH IMMEDIATELY WITH CLEAN WATER FOR 15 MINUTES AND OBTAIN MEDICAL ATTENTION 17 WARNING ONLY A QUALIFIED SERVICE TECHNICIAN SHOULD PROGRAM OR SERVICE THIS EQUIPMENT 18 CAUTION DO NOT OPERATE THE CHARGER IF IT HAS RECEIVED A SHARP BLOW BEEN DROPPED OR OTHERWISE DAMAGED HAVE A QUALIFIED SERVICE TECHNICIA...

Page 6: ...LUGS IMMEDIATELY Unpack the charger and examine it for shipping damage In the event that shipping damage is found report it as a claim with the freight company Do not operate the charger with a damaged AC or DC cable or connector Do not operate the charger if it has received a sharp blow was dropped or was otherwise damaged in any way Contact your dealer Proper installation is important to achieve...

Page 7: ...Summit Series 7 of 20 User s Manual Figure 2 1 Charger Mounting Recommendations Figure 2 2 Charger Dimensions and Mounting Slot Locations Case 1 ...

Page 8: ...in Figure 3 1 please contact your dealer for information To change the active battery profile for this charger please contact your dealer If the active battery profile is changed mark the charger ratings label or add an additional label or tag CAUTION THIS CHARGER IS FOR USE ONLY WITH BATTERY SYSTEMS OF THE SAME TYPE AS THE ACTIVE BATTERY PROFILE BATTERIES IMPROPERLY MATCHED WITH THE CHARGER MAY B...

Page 9: ...start a new charge cycle Disconnecting the DC output from the battery pack IS REQUIRED to automatically start a new charge cycle 4 2 On Board Chargers On board chargers are designed to be mounted on electric vehicles equipment If the DC output is connected to a battery pack of the proper voltage a charge cycle automatically starts when the AC input plug is connected to AC power unless a safety per...

Page 10: ... CHARGE ONLY IN WELL VENTILATED AREAS TO PREVENT ARCING OR BURNING NEAR BATTERIES DO NOT DISCONNECT THE DC CHARGING CONNECTOR S FROM THE BATTERIES WHEN THE CHARGER IS OPERATING IF THE CHARGE CYCLE MUST BE INTERRUPTED UNPLUG THE AC POWER CORD BEFORE DISCONNECTING THE DC OUTPUT CONNECTOR S FROM THE BATTERIES KEEP SPARKS FLAME AND SMOKING MATERIALS AWAY FROM BATTERIES TO REDUCE THE RISK OF FIRE DO NO...

Page 11: ...ubjected to severe deep cycle duty on a daily basis Although these batteries are designed to withstand such duty the following precautions must be observed to obtain good performance and maximum cycle life CAUTION ALWAYS WEAR PROTECTIVE EYE SHIELDS AND CLOTHING WHEN WORKING WITH BATTERIES BATTERIES CONTAIN ACIDS WHICH CAN CAUSE BODILY HARM DO NOT PUT WRENCHES OR OTHER METAL OBJECTS ACROSS THE BATT...

Page 12: ... attention immediately 5 NEVER smoke or allow a spark or flame to be in the vicinity of a battery 6 Be extra cautious to reduce the risk of dropping a metal tool onto a battery It could spark or short circuit the battery or other electrical components that could cause an explosion 7 Remove personal metal items such as rings bracelets necklaces and watches when working with a battery A battery can ...

Page 13: ...art automatically which is indicated by the Charge Status yellow LED beginning to blink slowly 3 If the charger must be disconnected from the battery while a charge cycle is in progress first disconnect the AC power cord from the AC outlet Do not disconnect the charger DC output connector plug from the battery while a charge cycle is in progress 4 The charge cycle 80 point is indicated by the Char...

Page 14: ...D beginning to blink quickly Not all charge profiles include a Balance Equalize phase 8 The charger automatically terminates the charge cycle when a battery reaches full charge which is indicated by 1 the solid illumination of the Charge Complete green LED or 2 the Charge Complete green LED beginning to blink slowly indicating a post charge phase The required charge time is affected by numerous fa...

Page 15: ...ible states FAULT red Indicates when a charger or battery fault has occurred See the FAULTS section Charge Status Yellow LED Charge Complete Green LED Description Slow Blink Off Bulk Start charge cycle phase constant power or constant current Fast Blink Off Absorption Plateau charge cycle phase constant voltage Greater than 80 charged Solid On Off Finish charge cycle phase constant current Not all...

Page 16: ... Lester Electrical Slow Blink Slow Blink 0 HARDWARE FAULT Contact Lester Electrical Slow Blink Slow Blink 1 HARDWARE FAULT Contact Lester Electrical Fast Blink N A N A HARDWARE FAULT Contact Lester Electrical Unit is still able to charge Battery 1 0 0 PHASE A fault condition most commonly maximum time was met during a particular charge cycle phase start bulk plateau absorption finish etc 1 0 Slow ...

Page 17: ...rge cycle b The charger DC output connector was disconnected from the battery during the charge cycle c The battery has been allowed to sulfate Charge the battery at least once every three 3 days when the equipment is lightly used Once sulfation is allowed to take place it may be partially reduced by returning temporarily to daily charging 3 A decrease in vehicle equipment range where the battery ...

Page 18: ... 21A 27940 27950 25 A Battery types Wet flooded AGM gel deep cycle lead acid lithium ion custom See Section 3 for additional details Protection Current limit short circuit reverse polarity under voltage over voltage wrong battery voltage LEDs Charge Complete green Charge Status yellow Fault red Lockout Control Optional Pulls down to battery neg when active See Section 7 for options and additional ...

Page 19: ...Summit Series 19 of 20 User s Manual NOTES ...

Page 20: ...Summit Series 20 of 20 User s Manual Represented By 39251H ...