8
Leslie 3300 Owner’s Manual
HOOK-UP AND LESLIE SETUP PROCEDURES
SINGLE CHANNEL HOOK-UP WITH AN 11-PIN LESLIE SOCKET
Applicable HAMMOND Models: New B-3, New C-3, B-3P, B-3M (Ultimo), XK-3 (NOTE 1), XK-2, XB-2, XB-5
THREE CHANNEL HOOK-UP WITH AN 11-PIN LESLIE SOCKET
Applicable HAMMOND Models: XE-1, XT-100, XH-200, XB-3, XC-3, XB-3M, XC-3M, 926, 935, XK-3 (NOTE 2)
1. Switch OFF the Power of the Organ.
2. Switch OFF (REMOTE) of the Power on the Leslie 3300.
3. Connect the optional 11-pin Leslie cable as shown above.
4. Set the VOLUME control on the Leslie to the 3 position, and turn the TUBE
DRIVE LEVEL to the fully counterclockwise position (TUBE OFF).
5. Switch ON the Power on the Organ. The Leslie 3300 will automatically
turn ON after a few moments and the Rotor Modo Indicator will light.
6. Switch the Leslie speeed switch on the organ from Slow to Fast. The rotors
in the Leslie 3300 should simultaneously change speeds from Slow to Fast
and the Rotor Mode Indicator lights should switch from Slow to Fast.
7. While playing the organ at maximum volume, adjust the Volume setting on
the Leslie for the desired volume level.
1. Switch OFF the Power of the Organ.
2. Switch OFF (REMOTE) the Power on the Leslie 3300.
3. Connect the optional 11-pin Leslie cable as shown above.
4. Connect the Powered Speakers (Leslie 2121 is recommendable) to the STA-
TIONARY OUT L, & R jacks as shown above.
5. Set the VOLUME control on the Leslie to the 3 position, and turn the TUBE
DRIVE LEVEL to the fully counterclockwise position (TUBE OFF). Set
the VOLUME control on the Powered Speaker to a suitable listening lelvel.
6. Switch ON the Power on the Organ. The Leslie 3300 will automatically
turn ON after a few moments and the Rotor Mode Indicator will light. Switch
ON the Power to the Powered Speaker (2121).
7. Switch the Leslie speed switch on the organ from Slow to Fast. The rotors
in the Leslie 3300 should simultaneously lights should switch from Slow to
Fast.
8. Switch the Leslie ON/OFF switch on the organ to the ON position and
select a Drawbar voice. While the Organ is being played at its maximum
Volume, adjust the VOLUME control on the Leslie to your desired setting.
9. If your organ has a Leslie Brake Switch, turn it OFF. While playing a Draw-
bar sound on the organ, turn OFF the Leslie ON/OFF Switch so that the
drawbar sounds are sent out to the Stationary Powered Speakers.
10. Adjust the VOLUME on the Powered Speakers so that the volume is bal-
anced between the Stationary Powered Speakers and the Leslie.
NOTE 1: The default setting of the XK-3 is for 1 channel.
NOTE 2: The XK-3 defalut setting must be changed from “1” to “2 or 3” channels.
Steps:
Steps: