LST-MAT1/MAT2
EN
LESITE
Error Code
Description Measures
“Error T002”
“Error S002”
“CT:999 Err-T001”
“Error FANerr”
No thermocouple
detected
No heating element
detected
Thermocouple failure
in operation
Overheating
a.Check thermocouple connection
b.Replace thermocouple
a.Check heating element connection
b.Replace heating element
a.Check thermocouple connection
b.Replace thermocouple
a.Check hot air blower
b.Clean nozzle and filter