  Maintenance and Cleaning 

A

  Maintenance 

a

  Changing the Dust Bag (TYPE KH 99)

You can see that the dust bag 

i

 is completely 

full when the filling level indicator 

q

 in the 

viewing window is 100 % RED.
•    Turn the vacuum cleaner off and disconnect 

the power cord 

A

 from the mains.

•    Press the release button 

{

 on the cover of 

the dust collection container and open the 
cover.

•    Remove the full dust bag 

i

 from the dust 

bag holder 

u

 by pressing the clamping 

lever.

•    Insert a new dust bag of TYPE KH 99 or 

type Swirl 

®

 Y 101 

®

 into the dust bag 

holder. 

Note:

If no dust bag is inserted it is not possible to 
close the cover!

a

  Changing the Filter 

•    Switch the vacuum cleaner off and disconnect 

the power cord 

A

 from the mains.

•    Press the release button 

{

 on the cover of 

the dust collection container and open the 
cover.

•    Remove the full dust bag 

i

 from the dust 

bag container 

u

 by pressing the clamping 

lever.

Motor Protection Filter

The motor protection filter 

o

 protects the motor 

compartment against dirt (see illustration B). 
•    Remove the motor protection filter 

o

 from 

the holder.

•   Replace the filter insert by another one.
•    Then reinsert the motor protection filter 

o

 

in the holder.

Exhaust Air Filter

The exhaust air filter 

p

 collects fine dusts 

which would otherwise be given off to the 
surrounding air. The exhaust air filter should be 
changed after a visual check (see illustration F). 
If a replacement is needed, this can be  
purchased from our service addresses.
•    Remove the exhaust air filter 

p

  

from the holder.

•    Replace the entire exhaust air filter  

by a new one.

•    Insert the new exhaust air filter 

p

 into the 

holder and allow it to click into place.

a

  Thread Catcher 

Through the use of the thread catchers on the 
underside of the floor nozzle 

I

, threads and 

fluff are vacuumed up particularly thoroughly. 
Worn thread catchers can be levered out with an 
appropriate tool. If a replacement is needed, this 
can be bought from our service addresses.

A

  Cleaning

•    Switch the vacuum cleaner off and discon-

nect the power cord 

A

 from the mains.

•   Please use a dry cloth for cleaning. 
•    The device should never be cleaned with 

moisture! 

•    Use a brush or tweezers to remove threads 

from the floor nozzle 

I

, or vacuum these 

off from time to time with the crevice 
nozzle 

r

.

Maintenance and Cleaning

KH3158_Inhalt_UK_IE.indd   10

05.07.2006   10:46:07 Uhr

Summary of Contents for 1500 AM KH 3158

Page 1: ...Lervia 1500 AM KH 3158 Floor Vacuum Cleaner Operation and Safety Notes Page 5 11 8 KH3158_Umschlag_UK IE indd 1 3 05 07 2006 10 47 19 Uhr ...

Page 2: ...1 D 44867 Bochum Germany Last Information Update 07 2006 Ident No KH3158 072006 1 UK IE A Q W E R T Y I O P q w e r t u p S F G C B E P U F D W R T Y u i p F U y i o p A o D KH3158_Umschlag_UK IE indd 4 6 05 07 2006 10 47 38 Uhr ...

Page 3: ...Use Assembly Page 8 Adjusting the Telescopic Suction Tube Page 8 Using the Suction Nozzles Page 8 Operation Mains Connection Page 9 Switching On and Off Page 9 Selecting the Suction Power Page 9 Transportation and Storage Page 9 Maintenance and Cleaning Maintenance Page 10 Changing the Dust Bag Page 10 Changing the Filter Page 10 Thread Catcher Page 10 Cleaning Page 10 Disposal Page 11 Information...

Page 4: ...egulator E Suction hose R Stainless steel telescopic suction tube T Release button Y Height adjuster for telescopic suction tube U Wheel I Floor nozzle with brush strip and thread catcher O Changeover switch for the floor nozzle P Retractable carrying handle Cover release Suction hose connector rotating q Filling level indicator for the dust bag w Exhaust air opening e Holder for additional nozzle...

Page 5: ...e vacuum cleaner Please ensure that no people or animals are hit by the vacuum cleaner Before connecting the vacuum cleaner to the mains power supply you should ensure that the mains supply is 230V 50Hz and is correctly equipped with a 16 Ampere fuse The device must only be assembled maintained and serviced when it is not connected to the power supply Do not allow the device to come into contact w...

Page 6: ...d by authorised and trained specialists A Initial Use A Assembly Press the cover release of the dust coll ection container and then open the cover Remove the dust bag holder u together with the dust bag i and ensure that the motor protection filter o and the exhaust air filter p are assembled as shown in illustration B Then reinsert the dust bag holder u together with the dust bag i Close the cove...

Page 7: ...switched on for approximately 3 more seconds Otherwise not all of the last dust that was vacuumed up will reach the dust bag A Selecting the Suction Power The indentation on the control S points to the selected suction power of the vacuum cleaner on the scale D see illustration C Turn the control S clockwise along the scale D in order to increase the suction power Turn the control S anticlockwise ...

Page 8: ...he holder Replace the filter insert by another one Then reinsert the motor protection filter o in the holder Exhaust Air Filter The exhaust air filter p collects fine dusts which would otherwise be given off to the surrounding air The exhaust air filter should be changed after a visual check see illustration F If a replacement is needed this can be purchased from our service addresses Remove the e...

Page 9: ...l authority A Information A Service Please see the attached guarantee card for the respective service address for your country A Manufacturer s Certificate Declaration of Conformity We Kompernass GmbH Burgstrasse 21 44867 Bochum Germany hereby declare that this product conforms to the following EC directives Low Voltage Directive 73 23 EEC 93 68 EEC Electromagnetic Compatibility 89 336 EEC 93 68 E...

Page 10: ...12 KH3158_Inhalt_UK_IE indd 12 05 07 2006 10 46 08 Uhr ...