GB/IE

·    Do not vacuum up any toner dust!
·    Do not cover the vacuum cleaner with other 

items! Otherwise it might be damaged by 
heat accumulation!

·    If you are not using the vacuum cleaner, 

please disconnect it from the mains and roll 
up the power cord completely! Otherwise 
there is a danger of injury if it is tripped 
over!

·    You should always use the handle when 

operating the vacuum cleaner. Vacuuming 
up fine dust results in static charges. You 
should therefore ensure permanent contact 
with the metal insert on the underside of 
the handle. This prevents the unpleasant 
effects of electrostatic discharge.

·    The device should never be used without a 

dust bag or filter!

Caution!

·    Please avoid any damage to the power 

cord!

·    During use the power cord should be 

unwound as far as the yellow marking! 
Otherwise there is a danger of damage 
from overheating!

·    During use the power cord should be  

unrolled at least as far as the yellow marking, 
but not past the red marking!

·    The power cord should only be removed 

from the socket by pulling the plug! 

·    Disconnect the vacuum cleaner from the 

mains immediately if there are any  
malfunctions!

·    If the vacuum cleaner / power cord is  

damaged or broken it should only be 
repaired by authorised and trained  
specialists!

A

  Initial Use

A

  Assembly 

•    Press the cover release 

{

 of the dust coll-

ection container and then open the cover.

•    Remove the dust bag holder 

u

 together 

with the dust bag 

i

 and ensure that the 

motor protection filter 

o

 and the exhaust 

air filter 

p

 are assembled as shown in 

illustration B. Then reinsert the dust bag 
holder 

u

 together with the dust bag 

i

.

•    Close the cover and insert the suction hose 

connector 

}

 into the suction opening of 

the floor vacuum cleaner until it locks in 
place.

•    Insert the tapered end of the telescopic 

suction tube 

R

 into the connector of the 

floor nozzle 

I

 until it locks in place. Insert 

the handle 

Q

 into the telescopic suction 

tube 

R

 until it locks in place.

a

  Adjusting the Telescopic Suction Tube 

•    Keep the height adjuster 

Y

 held down in 

the direction of the arrow (see illustration D).

•    Adjust the telescopic suction tube 

R

 to the 

desired length and lock it in place.

a

  Using the Suction Nozzles

The 

floor nozzle

 

I

 is suitable for the daily 

vacuuming of carpeted and hard floors. The floor 
nozzle 

I

 can be changed over manually - the 

brush strip is folded in and out.
•    Operate the changeover switch 

O

 of the 

floor nozzle in order to fold out the brush 
strip. This setting allows you to vacuum up 
loose dust, fluff and hairs on a smooth and 
solid surface, e.g. floor tiles.

Safety / Initial Use

KH3158_Inhalt_UK_IE.indd   8

05.07.2006   10:46:05 Uhr

Summary of Contents for 1500 AM KH 3158

Page 1: ...Lervia 1500 AM KH 3158 Floor Vacuum Cleaner Operation and Safety Notes Page 5 11 8 KH3158_Umschlag_UK IE indd 1 3 05 07 2006 10 47 19 Uhr ...

Page 2: ...1 D 44867 Bochum Germany Last Information Update 07 2006 Ident No KH3158 072006 1 UK IE A Q W E R T Y I O P q w e r t u p S F G C B E P U F D W R T Y u i p F U y i o p A o D KH3158_Umschlag_UK IE indd 4 6 05 07 2006 10 47 38 Uhr ...

Page 3: ...Use Assembly Page 8 Adjusting the Telescopic Suction Tube Page 8 Using the Suction Nozzles Page 8 Operation Mains Connection Page 9 Switching On and Off Page 9 Selecting the Suction Power Page 9 Transportation and Storage Page 9 Maintenance and Cleaning Maintenance Page 10 Changing the Dust Bag Page 10 Changing the Filter Page 10 Thread Catcher Page 10 Cleaning Page 10 Disposal Page 11 Information...

Page 4: ...egulator E Suction hose R Stainless steel telescopic suction tube T Release button Y Height adjuster for telescopic suction tube U Wheel I Floor nozzle with brush strip and thread catcher O Changeover switch for the floor nozzle P Retractable carrying handle Cover release Suction hose connector rotating q Filling level indicator for the dust bag w Exhaust air opening e Holder for additional nozzle...

Page 5: ...e vacuum cleaner Please ensure that no people or animals are hit by the vacuum cleaner Before connecting the vacuum cleaner to the mains power supply you should ensure that the mains supply is 230V 50Hz and is correctly equipped with a 16 Ampere fuse The device must only be assembled maintained and serviced when it is not connected to the power supply Do not allow the device to come into contact w...

Page 6: ...d by authorised and trained specialists A Initial Use A Assembly Press the cover release of the dust coll ection container and then open the cover Remove the dust bag holder u together with the dust bag i and ensure that the motor protection filter o and the exhaust air filter p are assembled as shown in illustration B Then reinsert the dust bag holder u together with the dust bag i Close the cove...

Page 7: ...switched on for approximately 3 more seconds Otherwise not all of the last dust that was vacuumed up will reach the dust bag A Selecting the Suction Power The indentation on the control S points to the selected suction power of the vacuum cleaner on the scale D see illustration C Turn the control S clockwise along the scale D in order to increase the suction power Turn the control S anticlockwise ...

Page 8: ...he holder Replace the filter insert by another one Then reinsert the motor protection filter o in the holder Exhaust Air Filter The exhaust air filter p collects fine dusts which would otherwise be given off to the surrounding air The exhaust air filter should be changed after a visual check see illustration F If a replacement is needed this can be purchased from our service addresses Remove the e...

Page 9: ...l authority A Information A Service Please see the attached guarantee card for the respective service address for your country A Manufacturer s Certificate Declaration of Conformity We Kompernass GmbH Burgstrasse 21 44867 Bochum Germany hereby declare that this product conforms to the following EC directives Low Voltage Directive 73 23 EEC 93 68 EEC Electromagnetic Compatibility 89 336 EEC 93 68 E...

Page 10: ...12 KH3158_Inhalt_UK_IE indd 12 05 07 2006 10 46 08 Uhr ...

Reviews: