31
INSTALLATION AND MAINTENANCE
VARMECA - 10
Variable speed motor or geared motor
OPERATING EXTENSIONS
LEROY-SOMER
Réf. 3195 - 4.33/d - 12.99
7 - OPERATING EXTENSIONS
7.1 - Option without control button (SD or SG)
The speed control button is no longer located on the VARMECA - 10 (the indicator lamp remains) but near the operator.
Ramp selection and selection of running direction can also be positioned close to the operator.
7.2 - Integrated run-stop control option (CMA)
With a Run key and a Stop key located on the cover, it is possible to control the VARMECA - 10 locally, once it has been powered
up, as required.
For a run command to be taken into account, the key must be held down for one second.
7.3 - Forward/Reverse/Stop control option (CMA VAR)
As with the CMA option, the keys are located on the cover. They are used to control the motor locally in both directions of rotation.
For an instruction to be taken into account, the relevant key must be held down for 1 second.
7.4 - EMC filter option (FLT VMA)
The filter is located in the VARMECA - 10 cover and is connected instead of connections 1-4, 2-5, and 3-6, paying attention to the
colour of the wires. It is essential to connect the filter PE terminal.
EMC filter option terminal
Blue
(terminal 7
or
8)
Black (terminal
4)
Red (terminal
1)
Yellow
EMC filter option terminal
Mauv
e (ter mina
l 7
)
Blue
(termina
l 8
)
Black
(termina
l 4
)
Red (termina
l 1
)
Yellow
en