Leonton EG5-0800 Series User Manual Download Page 3

 

 

FCC Notice

 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class-A  digital  device, 
pursuant  to  Part  15  of  the  FCC  rules.  These  limits  are  designed  to  provide  reasonable  protection 
against  harmful  interference  in  a  residential  installation.  This  equipment  generates,  uses,  and  can 
radiate  radio  frequency  energy.  It  may  cause  harmful  interference  to radio  communications  if the 
equipment  is  not  installed  and  used  in  accordance  with  the  instructions.  However,  there  is  no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful  interference  to  radio  or  television  reception,  which  can  be  determined  by  turning  the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of 
the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 
Caution: Any changes or modifications not expressly approved by the grantee of this device could 
void the user's authority to operate the equipment. 
 

 

Déclaration FCC 

Cet  équipement  a  été testé  et  reconnu  conforme  aux  limites  de  la  classe  A pour  les  équipements 

numériques, conformément à la section 15 des Réglementations FCC. Ces limites sont conçues pour 

fournir une protection raisonnable contre toutes interférences nuisibles dans un milieu résidentiel. 

Cet  équipement  génère,  utilise,  et  peut  émettre  de  l’énergie  de  fréquence  radio  et,  s’il  n’est  pas 

installé  et  utilisé  conformément  au  manuel 

d’instruction,  peut  perturber  la  réception  radio. 

Cependant,  il  n’est  p

a

s  garanti  que  l’équipement  ne  produira  aucune  interférence  dans  une 

installation particulière. Si cet équipement cause des interférences nuisibles à la réception radio ou 

télévisée, qu

i peuvent être déterminées en l’éteignant et le rallumant, l’utilisateu

r est encouragé à 

essayer de remédier au problème en prenant les mesures suivantes: 

* Réorienter ou déplacer l’antenne réceptrice.

 

* Augmenter la distance entre l’équipement et le récep

teur. 

* Connecter l’équipement à une prise secteur sur un circuit diffé

rent de celui utilisé par le récepteur. 

* Consulter le négociant ou un technicien radio/TV expérimenté. 

 

Attention: Tout changement ou modification non expressément approuvé par le concessionnaire de 

cet appareil pourrait annuler l'autorité de l'utilisateur à utiliser l'équipement. 

Summary of Contents for EG5-0800 Series

Page 1: ...LEONTON EG5 0800 Series EG5 0800 EG5 0800 T User Manual...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...he grantee of this device could void the user s authority to operate the equipment D claration FCC Cet quipement a t test et reconnu conforme aux limites de la classe A pour les quipements num riques...

Page 4: ...equired to take adequate measures CE Mark Avertissement Ceci est un produit de classe A Dans un environnement domestique ce produit peut tre utilis en pr sence d interf rences radio This document is t...

Page 5: ...Physical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 6 Cabling 7 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 Grounding Note 8 Mounting Installation 9 DIN Rail...

Page 6: ...erature of 10 to 65 C and another with a wide operating temperature of 40 to 75 C this series is designed to meet any needs for industrial automation outdoor application and harsh environments Key Fea...

Page 7: ...un dispositif de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage...

Page 8: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of EG5 0800 series W x H x D is 54mm x 142mm x 99mm Figure 2 1 Physical Dimensions...

Page 9: ...Front Panel Top View Figure 2 3 below shows the top panel of the EG5 0800 series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 48VDC Figure 2 3 T...

Page 10: ...s inactive FAULT Green On No event happened Red On 1 Power input 1 or 2 is inactive 2 Port link down Broken MASTER Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active RING...

Page 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45...

Page 12: ...rt the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 4 Figure 2 4 Power Terminal Block Step 2 Tighten the wire clam...

Page 13: ...1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Attention Le calibre des fils du bornier doit tre compris entre 12 et 24 AWG Si vous n utilisez qu une seule source d alimentation jumelez...

Page 14: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Page 15: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Page 16: ...strial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 17: ...ring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Prepare the twisted pair straight through category 5 cable for Ethernet connection Step 6 Inser...

Page 18: ...st me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agi...

Page 19: ...which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user...