SAFETY INSTRUCTIONS

 

Please read carefully and follow this user’s guide carefully and completely.

Important:  Please keep this user’s guide for reference in order to use the UPS properly and safety.  

 

 

This user’s guide consists of  safety instructions, introduction, front and rear panel, 

 

 

installation, operation and troubleshooting.

 

For product safety, please check this product annually by our service qualified personnel or if 

there are any symptom of problems which are not mentioned in this guide or any queries, please 

contact your LEONICS local distributors, LEONICS Service Center, send e-mail to support@leonics.

com or visit www.leonics.com

 

 

For your convenience and quick reference for our service, pleas fill the

 

 

requested informations in the blanks below:

   UPS 

Model:

   Serial 

Number:

   Purchased 

Date:

   Purchased 

From:

Warning

 

 

Risk of electric shock, DO NOT remove cover. No user serviceable part inside,

 

 

please refer servicing to qualified service personnel.

1.1 Electrical 

Safety

 

1.1.1  Do not work alone where there are electrically hazardous conditions.

 

1.1.2  Contact with live conductors will cause burns and dangerous electric shock.

 

1.1.3  Only qualified electricians allow to install and wiring this unit and system.

 

1.1.4  Periodically check your cable, outlets, terminal blocks and power source to make sure  

 

 

that they are in good condition.

 

1.1.5  To reduce risk from electric shock, if you can not find the electrical ground  (

) of    

 

 

the building, connect loads to UPS before plug in the UPS to AC power source. 

 

1.1.6  Do not touch any electrical connection when the unit is operating.

 

1.1.7  Use ONLY one hand when plugging or unplugging the loads in order to avoid electric  

 

 

shock from touching two surfaces with different potential.

 

1.1.8  It is recommended to connect the UPS to a three wires AC power source (two live wires 

 

 

and an electrical ground) which connects to a protected circuit such as employs a fuse 

- 2 -

 

 

or circuit breaker.

1.2  Safety instruction for installation and operation

 

1.2.1  Before installing or using this unit, read all instructions and caution markings on the   

 

 

UPS and all connected loads, and all sections of this user guide.

 

1.2.2  Install this unit in a temperature and humidity controlled indoor area with adequate  

 

 

air flow and away from chemical particles or flammable substances. Avoid installing   

 

 

the unit near radio transmission station, heat dissipation equipment and direct  

 

   sunlight.

 

1.2.3   This unit has ventilation grills. Ensure that sufficient ventilation is provided. DO NOT   

 

 

block the ventilation grills. The distance of minimum 30 cm. between the wall and the 

 

 

unit is necessary. 

 

1.2.4  Use insulated tools to reduce your risk of electric shock.

 

1.2.5  Remove all jewelry or other metal objects such as rings, necklace, bracelets and 

 

 

watches when installing this product.

 

1.2.6  Verify correct terminal block connections to prevent the damage occurs.

 

1.2.7  Before connecting the communication interface signal cable, turn off the UPS  and  

 

 

disconnect the UPS from utility power source.

 

1.2.8  Turn on the UPS before turn on all connected loads to prevent surge damage.

 

1.2.9  DO NOT connect the utility power source into the UPS OUTPUT. This may cause the    

   UPS 

damaged.

 

1.2.10  During a heavy rain storm, avoid using electrical appliances including the UPS to 

 

 

prevent damage from lightning strike.

 

1.2.11  Use soft cloth to clean the UPS when it is turned off. DO NOT clean it with solvent.

 

1.2.12  This UPS is not intended for use with life rescue equipment! A failure of the UPS might 

 

 

cause the life rescue equipment to fail and endanger human lives.

1.3 Battery 

Safety

 

1.3.1  The UPS has hazardous voltages inside, do not disassemble any parts of UPS except for 

 

 

the battery. Users are not allowed to repair, recondition or disassemble the UPS. This  

 

 

must be done by Leonics qualified technicians only. 

 

1.3.2  The UPS contains sealed lead acid battery and must be recycled properly. For recycling 

 

 

please return it to a LEONICS local distributor or LEONICS Service Center or contact    

 

 

your local recycling center for proper disposal information.

 

1.3.3  Do not dispose of battery in a fire. They may be exploded.

 

1.3.4  Do not disassemble battery. They contains poisonous electrolyte which is harmful to  

 

 

your skin and eyes.

 

1.3.5  Replace battery with the same type and rating.

Summary of Contents for VIPER

Page 1: ...on 1 1 3 Battery safety 2 2 INTRODUCTION 3 2 1 General 3 2 2 Features 3 2 3 Optional 3 2 4 Special Optional 4 3 FRONT AND REAR PANEL 4 3 1 Front panel 4 3 2 Rear panel 5 4 INSTALLATION AND OPERATION 6 4 1 Preparation 6 4 2 Installation 6 5 TROUBLESHOOTING 8 6 BATTERY REPLACEMENT 9 7 STORAGE 10 8 SOFTWARE INSTALLATION 10 ...

Page 2: ...nstructions and caution markings on the UPS and all connected loads and all sections of this user guide 1 2 2 Install this unit in a temperature and humidity controlled indoor area with adequate air flow and away from chemical particles or flammable substances Avoid installing the unit near radio transmission station heat dissipation equipment and direct sunlight 1 2 3 This unit has ventilation gr...

Page 3: ...the laser printer from surges This outlet does not supply backup power when power fails Automatic No load shutdown UPS shuts down itself automatically when there is no connected load when power fails in order to save battery power Automatic restart After the utility line turns back to normal UPS will restart itself automatically Automatic UPS and Battery Test When startup the UPS it will start tes...

Page 4: ...own when power fails and there is no connected loads Total power of all connected loads are lower than 60 Watt This special optional switch is not supplied with the standard product 6 3 2 9 Additional UPS Output option The special optional extra Europe CEE 7 socket which is connected to UPS backup power system These special optional socket is not supplied with standard product INSTALLATION AND OPE...

Page 5: ...e condition of the internal battery Only connect the UPS to utility line and turn on then leave the UPS connected to utility line for at least 8 hours 8 TROUBLESHOOTING Symptoms Possible causes Solutions Turn on POWER switch LINE indicator extinguished and alarm sounds but UPS oper ates normally AC INPUT power cord is not properly plugged in to the utility line Properly plug in the AC INPUT power ...

Page 6: ...storage UPS for long period of time be sure that battery is fully charged and it need to be recharged every three months to preserve the condition of the internal battery 7 1 Plug the AC INPUT power cord to utility line 7 2 Turn on the POWER switch and leave the UPS connected to the utility line for at least 8 hours 7 3 Test the UPS by following the section 4 2 8 7 4 Turn off the UPS and disconnec...

Page 7: ...ely installed Open the Easy Mon X Setup Then click Auto Detect UPS button to search for UPS and communication port automatically 8 8 Once the location of UPS communication port has been found Open the Easy Mon X Spy program to monitor power data and operating status of the UPS LEN MAN UPS 107 Rev 3 00 2012 www leonics com Copyright 2012 Leonics Co Ltd All rights reserved ...

Reviews: