26
Установка
Instalación
Installation
Installation
Installation
Installazione
Serial number plate reading
Fig.7.
The serial number is on the right hand side of the appliance.
It provides important technical information that is vital in case of
a request for maintenance or repair of the appliance: please do
not remove, damage or modify it.
Smoke extraction
Fig.8.
The oven is fitted with an adjustable exhaust in the top to get rid
of the steam from the cooking chamber.
This steam, together with the one from the door during the work
phases,
must be conveyed outside
in one of the following
ways:
•
A
through a
hood supplied by the Manufacturer
that
ensures perfect compatibility with the oven. For correct
assembly and fixing to the oven, see the sheet attached to it; the
evacuation flue must be for the exclusive use of the appliance,
comply with current regulations and have a diameter that allows
the passage of a
150 mm [Ø5.91 in.]
which corresponds to the
diameter of the tube to be fitted on the hood (not supplied).
•
B
through a
hood supplied by the user
, of suitable
capacity, placed at
300 mm
[11.81in.]
from the oven,
minimum;
•
C
through an adequate
extraction system
supplied by the
user: in this case a draught switch must be installed
between the extractor and the oven chimney (the extractor
and switch are not supplied by the Manufacturer). In this type
of installation, the fumes resulting from the opening of the door
will not be extracted.
Electrical connection
Fig.9.
The electrical connection must be carried out
exclusively
by qualified personnel after reading the
safety warnings at the beginning of the manual.
Before connecting the oven,
check that the systems
comply with the regulations in force
in the country
where it is going to be used and with
the specifications
on the appliance rating plate
on the RH side of the oven.
The appliance is supplied without either power cable or plug:
they must both be fitted by qualified personnel. The cable must
be only
of the type stated
and the plug fitted to it must be
suitable for the consumption and connection of the oven to the
electrical mains.
If the oven has a twin or triple chamber, the power cables
to be connected are two or three as the connecting
plugs.
To connect the cable to the appliance, remove the RH side panel
of the oven, let the cable through the cable gland provided and
connect it to the terminal block correctly.
For a correct electrical connection, the appliance must:
• be included in an
equipotential system
in compliance with
the legislation in force.
This connection must be made between
the various devices with the terminal marked with the equipotential
symbol
. The cable must have a maximum cross-section of
10 mm2 (in compliance with IEC EN 60335-2-42:2003-09) and must
be yellow-green;
• must be
grounded
to the mains (green-yellow wire);
• must be connected to a
thermal differential switch
in
compliance with the regulations in force (0.03A A type);
• must be connected to an
omnipolar circuit breaker
allowing
complete disconnection in overvoltage III category conditions.
The Manufacturer accepts no liability for failure to comply with
the above.
If required, the cable can be replaced by the Dealer or its
technical service or by a person with similar qualifications
to prevent any risk.
Summary of Contents for LN2T/1TS