Attention to your operating

• 

Never  carry  the  pump  by  its  cable  and  do  not  pull  the  cable  to  disconnect  it.  For 

submerging, lifting or securing the pump, fix a rope to the pump^ carrying handle is 
the correct choice. 

• 

Do not pull out the power cable from the socket as a method of turning the pump off. 

Check  out  if  the outlet  and  the  inlet of the  pump  clog.  Clear the  outlet  and  the  inlet 
when need. 

Automatic protection for safety:

 

• 

Thermal  motor  protector:  The  pump  is  automatically  switched 

off on overheating by the built-in thermal motor protector. After 
having cooled down, the motor automatically switches on again. 

• 

Automatic Air bleed valve:  The 

automatic  air  bleed  valve  eliminates  any  air  pockets  in  the 
pump.

 

 

During this process,  air escapes through the plastic plug on the 
pump and air bubbles appear underwater. This is not a defect of 
your pump, but serves to deaerate the pump, but serves to remove 
air  from  the  pump.  It  may  take  several  seconds  for  the  air  to 
escape when the pump is immersed for the first time. 
 

Note: 

The position of vent hole may be different in some models. 

 

Main power cables must not have a smaller cross-section than the rubber-sheathed 
cables of the designation H05RN-F while the pump without power cable lighter than 5 
kg and the designation H07RN-F while the pump without power cable heavier than 5 
kg. The cable length must be at least 10m. 

Operation

 

Automatic operation of the float switch

:

 

The float switch 4 turns the pump on automatically when the water level exceeds the 
cut-in height and the water is pumped out. The float switch 4 turns the pump off again 
as soon as the water level falls below the cut-out hight. 

(1) 

Stand the pump on a firm surface or use a rope attached through the bore hole in 
the carrying handle 6 to immerse the pump in a well or shaft.

 

(2) 

During automatic operation, ensure that the float switch 4 can move freely.

 

Plug the power cable 3 into a mains socket.

 

Adjusting the Cut-in and Cut-out Height: Push the cable of 
the float switch 4 into the float switch lock 5.

 

Do not select a cable length that is too long or short to 
ensure that the float switch 4 can turn on and off properly.

 

 

The cable length between the float switch 4 and the float 
switch lock 5 must always be at least 10 cm.

 

Summary of Contents for XKS-400PW

Page 1: ...Acquaer Ltd H 4900 Fehérgyarmat Szatmári út 11 GARDEN SUBMERSIBLE PUMP Instruction Manual XKS ...

Page 2: ...struction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Attention If the appliance or the supply cord is damaged it must be repaired by manufacturer its service agent or qualified person Do not dispose of electrical appliances as unsorted mu...

Page 3: ...he length of life of the pump will be shortened accordingly if used in this way Corrosive chemicals cleaning fluids etc flammable or explosive substances e g petrol paraffin cellulose thinners grease oil salt water and sewage must not be conveyed by the pump The PH of water must between 6 5 and 8 5 Pollution of the liquid could occur due to leakage of lubricants The temperature of the liquid conve...

Page 4: ...for the first time Note The position of vent hole may be different in some models Main power cables must not have a smaller cross section than the rubber sheathed cables of the designation H05RN F while the pump without power cable lighter than 5 kg and the designation H07RN F while the pump without power cable heavier than 5 kg The cable length must be at least 10m Operation Automatic operation o...

Page 5: ...y by raising the float switch 4 as showed on the left 1 Stand the pump on a firm surface or use a rope attached through the bore hole in the carrying handle 6 to immerse the pump in a well or shaft 2 Plug the power cable 3 into a mains socket left drawing with the side of cable at the bottom As long as the float switch is positioned vertically with the cable at the bottom the pump will operate reg...

Page 6: ...onnect plug and clean feed impeller Release the pipe The pump won t stop The float switch is blocked in the upper part Release the float and reposition the pump The flow rate is inadequate The intake filter is clogged Pumping flow rate falls because the pump is clogged with water impurities Clean the filter Clean the pump and its environment The pump stops after working for a short time Dirty part...

Page 7: ... to material or manufacturing faults will be rectified exclusively by our contracted workshops the seller has the right to remedy a defect in your vicinity or by the manufacturer if the latter is closer Any claims going beyond the provision of a guarantee are ruled out Any transport damage should be reported not to us but to the shipper in question since otherwise any compensation claims the shipp...

Reviews: