Where to use your Pump 

Correct use:

 

  The pump is intended for private use around the house and garden. It is 

primarily intended for drainage purposes if flooding occurs but also for 
transferring water to and from tanks and pumping them out, for drawing water 
from wells and shafts, for draining boats and yachts and for aerating and 
circulating water for limited periods. 

Liquid conveyed:

 

  The pump is suitable for conveying:

 

  Submersible pump for clean water: clean to slightly dirty water with a max. 

particle size of 5 mm.

 

  Submersible pump for dirty water: dirty water with a max. particle size of 35 

mm. 

  The pump can be fully submerged (watertight encapsulation) and can be 

lowered down to a depth of 7m into the water.

 

  The pump must not be installed in swimming pools; it must be installed and 

used in accordance with National installation rules. 

  The pump is not intended for long term use (e. g. use for continuous 

circulation) in a pond. The length of life of the pump will be shortened 
accordingly if used in this way. 

  Corrosive (chemicals, cleaning fluids etc...), flammable or explosive 

substances (e.g. petrol, paraffin, cellulose thinners); grease, oil, salt water and 
sewage must not be conveyed by the pump.

 

  The PH of water must between 6.5 and 8.5. Pollution of the liquid could occur 

due to leakage of lubricants.

 

  The temperature of the liquid conveyed may not exceed 35 

°C.

 

  Do not expose the plug to damp. Protect plug and power cable away from 

heat, oil and sharp edges.

 

  Do not expose the pump to frost.

 

  Do not run the pump without water.

 

Safety Instructions 

Before starting up the pump make sure that:

 

• The pump must not be used when people are in the water. 

• Make sure that the electrical plug and socket connections are fitted in an area which 

cannot flood. And protect power plug from moisture. 

• Check out if there is any damage to the pump, especially to the cable and plug. A 

damaged pump mustn’t be used any way. 

• The pump must be supplied through a residual current device (RCD) having a rated 

residual operating current not exceeding 30 mA. 

The mains supply voltage matches the voltage indicated on the pump identification 

plate. 

Summary of Contents for XKS-400PW

Page 1: ...Acquaer Ltd H 4900 Fehérgyarmat Szatmári út 11 GARDEN SUBMERSIBLE PUMP Instruction Manual XKS ...

Page 2: ...struction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Attention If the appliance or the supply cord is damaged it must be repaired by manufacturer its service agent or qualified person Do not dispose of electrical appliances as unsorted mu...

Page 3: ...he length of life of the pump will be shortened accordingly if used in this way Corrosive chemicals cleaning fluids etc flammable or explosive substances e g petrol paraffin cellulose thinners grease oil salt water and sewage must not be conveyed by the pump The PH of water must between 6 5 and 8 5 Pollution of the liquid could occur due to leakage of lubricants The temperature of the liquid conve...

Page 4: ...for the first time Note The position of vent hole may be different in some models Main power cables must not have a smaller cross section than the rubber sheathed cables of the designation H05RN F while the pump without power cable lighter than 5 kg and the designation H07RN F while the pump without power cable heavier than 5 kg The cable length must be at least 10m Operation Automatic operation o...

Page 5: ...y by raising the float switch 4 as showed on the left 1 Stand the pump on a firm surface or use a rope attached through the bore hole in the carrying handle 6 to immerse the pump in a well or shaft 2 Plug the power cable 3 into a mains socket left drawing with the side of cable at the bottom As long as the float switch is positioned vertically with the cable at the bottom the pump will operate reg...

Page 6: ...onnect plug and clean feed impeller Release the pipe The pump won t stop The float switch is blocked in the upper part Release the float and reposition the pump The flow rate is inadequate The intake filter is clogged Pumping flow rate falls because the pump is clogged with water impurities Clean the filter Clean the pump and its environment The pump stops after working for a short time Dirty part...

Page 7: ... to material or manufacturing faults will be rectified exclusively by our contracted workshops the seller has the right to remedy a defect in your vicinity or by the manufacturer if the latter is closer Any claims going beyond the provision of a guarantee are ruled out Any transport damage should be reported not to us but to the shipper in question since otherwise any compensation claims the shipp...