Assembly of ICN connectors
NOTICE
Live cables!
Possible destruction of the connector.
▶
Never remove connector when voltage is being applied!
▶
Disable inverter before removing the connector!
NOTICE
Loss of the protection class due to incorrect mounting!
Malfunctions may occur.
▶
ICN connector with screwed connection: Do not remove O-ring
▶
ICN connector with bayonet lock: remove O-ring and dispose of it.
1
1. When connecting the connector to the motor connector, make sure that the aids to
orientation (pos. 1) are facing each other.
2. Tighten the box nut of the connector!
Motors with additional PE conductor connection
As an additional protective measure, a second PE conductor can be connected at the motor
housing if required:
•
Use PE-labelled bore hole at the motor housing
•
Remove coating for contact surface in the area of the bore hole
•
Ensure a good electrical conductivity of the contact
•
Establish a permanently safe electrical connection
Electrical installation
Motor connection
Connection via ICN connector
26