Configuration
Windows XP
LDCDS−MC−PNx DE/EN 2.0
44
H1_konfig−Einsatz_MC_PBx_CE_Hin
2. Assign the bus−specific firmware file to the communication channel 0 (CH#0):
– Go to the object tree and open the
Active Devices
folder and the (sub) folder of the
communication card (e.g.
cifX0 ( )
) you want to configure.
– Click the communication channel you want to assign to a firmware file. The
respective dialog page is displayed.
– Go to the
Downloads (Modules)
area, click the
Add
button and select the firmware
file (*.nxf) in the following menu.
– Confirm the selection with
OK
. The file path and the name of the firmware file are
displayed in the "File" list.
– Click the
Apply
button.
3. Exit the "cifX Driver Setup Utility" application via the
File
Quit
menu.
Note!
Only for MC−PNC (Controller):
ƒ
Configure the bus via the host application or the bus configurator
"SyCon.net".
Only for MC−PND (Device):
ƒ
Configure the bus via the warm start parameters in the "cifX Driver Setup
Utility". Further information can be obtained from the online help of the
"cifX Driver Setup Utility" and the documentation of Hilscher.