6
Electrical installation
Important notes
EDKRBP082R DE/EN/FR/ES/IT 8.0
50
l
H1_E_INST−eInstall_EN
6
Electrical installation
Important notes
(
Stop!
Possible overheating of the brake resistor during operation
Inadequate heat dissipation during operation can cause the brake resistor to
overheat.
Possible consequences:
ƒ
The brake resistor is destroyed.
ƒ
The drive is not braked but coasts to a standstill.
Protective measures:
ƒ
Always connect the thermal contact of the brake resistor.
ƒ
Integrate the thermal contact into the overall equipment monitoring
apparatus in such a way that the supply of power to the standard device is
switched off if the brake resistor overheats (e.g. switch−off by means of
mains contactor control).