Electrical installation
Ethernet connection
2
EDK94AZCEH DE/EN/FR/ES/IT 1.0
21
H2_EthernetAnschluss-BelegungPort 1
Ethernet connection
Note!
Please use prefabricated standard cables (corresponding to ISO/IEC 11801 or
EN 50173) only:
ƒ
cable type S/FTP
ƒ
category CAT 5e
Pin assignment
E94ZCEH004
PIN
Pin assignment for port 1 (connection A1)
Pin assignment for ports 2 - 8
(connections A2 ... A8)
MDI (not crossed)
MDIX (crossed)
1
Tx +
Rx +
Rx +
2
Tx -
Rx -
Rx -
3
Rx +
Tx +
Tx +
4
-
-
-
5
-
-
-
6
Rx -
Tx -
Tx -
7
-
-
-
8
-
-
-