Electrical installation
Connection data
EDK94AZHN25 DE/EN/FR/ES/IT 2.2
41
H1_E_INST−−−−(DUMMYSEITEVOR)−−−
Control connection
Terminal X117
Labelling
Description
DI
Digital input
GI
GND digital in
DO
Signalling output
24V
24−V supply by safely separated power supply unit
(SELV/PELV)
SSP94A6117
GND
GND digital out
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.5 ... 2.5
20 ... 12
Spring terminal
With wire end
ferrule
Stripping length or contact length: 8 mm
Digital output DO
State
Description
HIGH
No fault
LOW
Fault
l
Supply voltage of the motor holding brake is missing
l
Motor holding brake is not connected
l
Brake cable is defective
– Open circuit
– Short circuit
l
Supply voltage of the motor brake control is missing