6.1.7
Virtual mode
The application can be tested without a connected motor. For this purpose, the setpoint selec-
tion for the drive can be interrupted.
When the virtual mode is active, the setpoints generated in the application are not transmit-
ted to the drive. The actual values (e. g. position and velocity) are generated from the set-
points.
The kinematic parameters do not have any influence in the virtual mode. Only the parameters
travel range and cycle length are used for the machine measuring system.
Machine measuring system parameters
•
•
For diagnostic purposes, an active virtual mode is displayed in the Status word parameter.
Bit 0
Parameter
Address
Name / setting range / [default setting]
Info
0x500A:029
Virtual mode
•
Setting can only be changed if the inverter is inhibi-
ted.
false Inactive
true Active
Technology application (TA) basic settings