10.3.4
Control commands and status information
The following control commands can be executed in the "cyclic sync velocity mode" via the
CiA402 control word (
):
Control word
State
Function
Bit 4
0
reserved (bit must be set to "0")
Bit 5
0
reserved (bit must be set to "0")
Bit 6
0
reserved (bit must be set to "0")
Bit 8
0 ↗ 1
Stop
The following status information are output via the CiA402 status word (
) in the "cyclic
sync velocity mode":
Status word
State
Meaning
Bit 12
0
"Cyclic sync velocity mode" is inactive
1
"Cyclic sync velocity mode" is active
Configure speed control