20
Lenze 13466184 EDBSL03 v20
EN
, DE, FR, IT, ES
Trouble Shooting & Fault Elimination
Status
Cause
Remedy
e.g.
50
.
0
Present output frequency
Trouble free operation
OFF
Stop
(outputs U, V, W inhibited)
LOW signal at terminal 28
Set terminal 28 to HIGH
1nh
Inhibit
(outputs U, V, W inhibited)
Controller is set up for remote
keypad or serial control (see C01)
Start the controller via the remote
keypad or serial link
stP
Output frequency = 0 Hz
(outputs U, V, W inhibited)
Setpoint = 0 Hz (C31 = 0)
Setpoint selection
Quick stop activated through digital
input or serial link
Deactivate Quick stop
br
DC-injection brake active
DC-injection brake activated
• via digital input
• automatically
Deactivate DC-injection brake
• digital input = LOW
• automatically after holding time
c06 has expired
CL
Current limit reached
Controllable overload
Automatically (see C22)
LU
Undervoltage on DC bus
Mains voltage too low
Check mains voltage
dEC
Overvoltage on DC bus during
deceleration (warning)
Excessively short deceleration time
(C13, c03)
Automatically if overvoltage
< 1 s,
OU
, if overvoltage > 1 s
nEd
No access to code
Can only be changed when the
controller is in
OFF
or
1nh
Set terminal 28 to LOW or inhibit
by serial link
rC
Remote keypad is active
Attempt to use buttons on front of
controller
Buttons on front of controller are
disabled when remote keypad is
active
Error
Cause
Remedy
(1)
cF
Data on EPM not valid
Data not valid for controller
• Use EPM providing valid data
• Load Lenze setting
CF
Data error
GF
OEM data not valid
F1
EPM error
EPM missing or defective
Power down and replace EPM
CFG
Digital inputs not
uniquely assigned
E1...E3 assigned with the same
digital signals
Each digital signal can only be
used once
Either just “UP” or “DOWN” used
Assign the missing digital signal to
a second terminal
dF
Dynamic braking fault
Dynamic braking resistors are
overheating
Increase deceleration time
EEr
External error
Digital input “TRIP set” is active
Remove external error
Internal fault
Please contact Lenze
FC3
Communication error
Serial timer has timed out
Check serial link connections
FC5
Communication error
Serial communication failure
Please contact Lenze
JF
Remote keypad fault
Remote keypad disconnected
Check remote keypad connections
LC
Automatic start inhibited
c42 = 0
LOW-HIGH signal change at
terminal 28
5
Troubleshooting and fault elimination
(1) The drive can only be restarted if the error message has been reset; see c70
F2...F0
Summary of Contents for ESMD112L2YXA
Page 24: ...Notes...
Page 46: ...Notizen...
Page 69: ...Notes...
Page 70: ...Notes...
Page 92: ...Notes Notizen Nota...
Page 115: ......