Wiring the installation backplane
Connection plan
5
46
EDK94PNE36 DE/EN/FR/ES/IT 2.0
5.2
Connection plan
L3
N
PE
L1
L2
F1...F3
R
B
E94AxxExxxx
E94AZPxxxxx
X109
X110
Z1
E94APNE0xx4
24E GE
X11
E94AZPxxxxx
X109
X110
L1
L2
L3
X111
+UG -UG
L1 L2 L3
X112
Rb1 Rb2
K1
F4
K1
K1
O
I
R
B
J
+
-
3
+
+
SSP94PSP21
Fig.12-1
Example circuit for installation backplane and DC power supply module
E94APNE0xx4
9400 DC power supply module
E94AZPxxxxx
Installation backplane
E94AxxExxxx
9400 axis module
F1 ... F4
Fuses
Z1
Mains filter/RFI filter (optional)
K1
Mains contactor
RB
Brake resistor
c
Alternative: mains connection at the bottom
d
24 V supply voltage for control electronics according to IEC 61131-2