DC−bus operation
EMC in DC−bus operation
Compliance with EMC category C3 (industrial premises)
l
122
EDS700ACBA EN 5.1
7.7
EMC in DC−bus operation
7.7.1
Compliance with EMC category C3 (industrial premises)
Applications for the "second environment" on industrial premises must comply with EMC
category C3.
Observe the conditions for the compliance with EMC category C3:
ƒ
The permissible motor cable length is
£
50 m for each axis.
ƒ
The maximum sum of all motor cable lengths (
S
l
mot
) must be observed.
ƒ
Without a mains choke: 4 axes x 50 m = 200 m
– Switching frequency: 4 & 8 kHz
ƒ
With the mains chokes assigned: 10 axes x 50 m = 500 m
If the number of axes deviates,
S
l
mot
can be determined from the following diagram.
C3
-
MC
C3
-N
R
2
4
6
8
10
1
2
14
16
1
8
2
0
n
50
100 150
2
00
2
50
3
00
3
50 400 450 500
S
l
[m]
mot
E70EMCX001 b
Fig. 7−2
Motor cable lengths for the compliance with category C3
n
Number of axes
S
l
mot
Sum of the motor cable lengths ...
C3−NR
without mains chokes, according to the number of axes, for switching
frequency 4 & 8 kHz
C3−MC
with mains chokes, according to the number of axes
Summary of Contents for E70AC Series
Page 1: ...EDS700ACBA Usx Usx Hardware Manual i700 l E70AC Servo Inverter i700 Translation...
Page 2: ...0Fig 0Tab 0...
Page 75: ...Mechanical installation 5 l 75 EDS700ACBA EN 5 1...
Page 147: ...Accessories overview Terminals 11 l 147 EDS700ACBA EN 5 1 E70AZEVK001 i700ZM001 A...
Page 148: ...Accessories overview Terminals 11 l 148 EDS700ACBA EN 5 1 E70AZEVK002 i700ZM001 C...
Page 149: ...Accessories overview Terminals 11 l 149 EDS700ACBA EN 5 1 E70AZEVK003 i700ZM001 B...
Page 150: ...Accessories overview Terminals 11 l 150 EDS700ACBA EN 5 1 E70AZEVK004 i700ZM001 D...
Page 151: ...Accessories overview Terminals 11 l 151 EDS700ACBA EN 5 1 E70AZEVK005 i700ZP005 a...
Page 152: ...Accessories overview Terminals 11 l 152 EDS700ACBA EN 5 1 E70AZEVK006 i700ZP005 b...
Page 161: ......