14
Parameter reference
14.1
Parameters of the standard device that are relevant to communication
98
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00637
C01120
C01501
Parameter | Name:
C00637 | Resp. to new module in MXI2
Data type: UNSIGNED_32
Index: 23939 = 0x5D83
Response if a new module has been plugged into module slot 2 of the standard device.
Selection list
(Lenze setting printed in bold)
1 Fault
6 Information
5 Warning
4 Warning Locked
3 Quick stop by trouble
0 No response
Read access
Write access
CINH
PLC-STOP
No transfer
Parameter | Name:
C01120 | Sync source
Data type: UNSIGNED_8
Index: 23455 = 0x5B9F
Selection of the source for DC synchronisation signals.
• Depending on the slot in the standard device, set the selection "4: Module in MXI1" or "5: Module in MXI2" for
the communication module.
• The drive can only be synchronised by one source.
Synchronisation with "Distributed clocks" (DC) (
Selection list
(Lenze setting printed in bold)
0 Off
1 CAN on board
2 CAN module
4 Module in MXI1
5 Module in MXI2
6 Digital input 1
... ...
13 Digital input 8
Read access
Write access
RSP
PLC-STOP
No transfer
Scaling factor: 1
Parameter | Name:
C01501 | Resp. to comm. error with MXI1
Data type: UNSIGNED_32
Index: 23074 = 0x5A22
Response to a communication error between an "intelligent" module in slot 1 and the standard device
Selection list
(Lenze setting printed in bold)
0 No response
1 Fault
3 Quick stop by trouble
4 Warning Locked
5 Warning
Read access
Write access
CINH
PLC-STOP
No transfer