Parameter | Name:
C14879 | Bus error
Data type: UNSIGNED_32
Index: 9696 = 0x25E0
Bit-coded display of the bus error
Additionally, an error message is entered in the EtherCAT register "
"
.
Value is bit-coded:
Info
Bit 0 General bus error
Bit 1 Reserved
... ...
Bit 31 Reserved
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14880 | Resp. to communication failure
Data type: UNSIGNED_8
Index: 9695 = 0x25DF
The set response will be executed if ...
• a sync telegram failure has been detected or
• the device detects that is no longer in the "Operational" state and the monitoring time (
) has elapsed.
Selection list
0 No response
1 Fault
3 Quick stop by trouble
4 Warning Locked
6 Information
Subcodes
Lenze setting
Info
C13880/1
0: No Response
Interruption of EtherCAT communication (
C14880/2
0: No Response
Resp. to
Sync telegram failure detection (
(
available from SW version 04.00
)
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14881 | Response time when exiting 'Operational'
Data type: UNSIGNED_16
Index: 9694 = 0x25DE
If the "Operational" state is exited, the response parameterised with
occurs after the time set here has
elapsed.
A change of monitoring will be effective immediately.
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
65535
0 ms
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT