Technical data
Control terminals
Digital inputs
64
EDS84DPS424 EN 5.0
4.7
Control terminals
4.7.1
Digital inputs
X41 ... X43
Pin / Name
Features
Rated value
4 / DI1
2 / DI2
Digital input 1/2 at X41
according to IEC 61131−2, type 1
or
two−track frequency input for HTL encoder
0 ... 100 kHz
4 / DI3
2 / DI4
Digital input 3/4 at X42
according to IEC 61131−2, type 1
DI4 − typical delay time:
5
s at rising edge
25
s at falling edge
4 / DI5
2 / DI6
Digital input 5/6 at X43
according to IEC 61131−2, type 1
or
Single−channel frequency input, 0 ... 10 kHz
DI5/DI6 − typical delay time:
5
s at rising edge
25
s at falling edge
1 / 24O
3 / GIO
24 V supply of the external sensors or
potential−free contacts
External supply at 24E: Voltage drop < 2.5 V
Total current for X4x, X50/X8x
1 A
Extensions in the EMS version
X45 ... X48
Pin / Name
Features
Rated value
4 / DI7
2 / DI8
Digital input 7/8 at X45
according to IEC 61131−2, type 1
4 / DI9
2 / DI10
Digital input 9/10 at X46
(configurable with DO3/DO4)
4 / DI11
2 / DI12
Digital input 11/12 at X47
4 / DI13
2 / DI14
Digital input 13/14 at X48
5 / n. c.
not assigned
−
1 / 24O
3 / GIO
24 V supply of the external sensors or
potential−free contacts
External supply at 24E: Voltage drop < 2.5 V
Total current for X41 ... X48
1 A
Summary of Contents for 8400 protec
Page 2: ...0Fig 0Tab 0...
Page 190: ...Appendix Declarations and certificates 13 190 EDS84DPS424 EN 5 0...
Page 191: ...Appendix Declarations and certificates 13 191 EDS84DPS424 EN 5 0...
Page 192: ...Appendix Declarations and certificates 13 192 EDS84DPS424 EN 5 0...
Page 193: ...Appendix Declarations and certificates 13 193 EDS84DPS424 EN 5 0...
Page 194: ...Appendix Declarations and certificates 13 194 EDS84DPS424 EN 5 0...