15
E
Select any locomotive address on the manual control.
Don’t worry:
If a locomotive with the
selected address is placed on the track during activation, its settings will not be affected
because CV7 can only be read but not changed.
Change to "PoM"
Select CV7
Program the value 50 into CV7. This switches the LZV100 / LV102 into setting mode; the LED
of the LZV100 / LV102 shows a double-flash.
You have 15 seconds to program the value 93 for activating the RailCom function into CV7.
The LED will shine constantly and RailCom is activated.
If you want to deactivate RailCom (i.e. disable the blanking interval (cutout)), proceed as follows:
Change to "PoM"
Select CV7
Program the value 50 into CV7. This switches the LZV100 into setting mode; again, the LED of
the LZV100 shows a double-flash.
You have 15 seconds to program the value 92 for deactivating the RailCom function into CV7.
Again, the LED will shine constantly and RailCom is deactivated.