Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3.
Remove the cover (see “Removing the cover” on page 240).
Step 4.
Remove the air baffle (see “Removing the air baffle” on page 241).
Step 5.
Align the retention module with the holes on the system board.
Step 6.
Use a screwdriver to reinstall the four screws.
Figure 257. Heat-sink retention module installation
Step 7.
Reinstall the heat sink (see “Replacing a microprocessor and heat sink” on page 330).
Attention:
Make sure that you install each heat sink with its paired microprocessor.
Step 8.
Reinstall the air baffle (see “Replacing the air baffle” on page 242).
Step 9.
Install the cover (see “Replacing the cover” on page 240).
Step 10. Slide the server into the rack.
Step 11. Reconnect the power cords and any cables that you removed.
Step 12. Turn on the peripheral devices and the server.
Removing the system board
Use this information to remove the system board.
Notes:
1. When you replace the system board, you must either update the server with the latest firmware or
restore the pre-existing firmware that the customer provides on a diskette or CD image. Make sure that
you have the latest firmware or a copy of the pre-existing firmware before you proceed.
2. When you replace the system board, make sure that you remove the Integrated Management Module
Advanced Upgrade and place it on the new system board. For information about the Advanced
Upgrade, see “Using the remote presence and blue-screen capture features” on page 153.
3. Before you replace the system board, make sure that you back up any features on demand (FoD) keys
that were enabled. Reactivate any Features on Demand features. Instructions for automating the
activation of features and installing activation keys is in the
Features on Demand User's Guide
. To
download the document, go to https://fod.lenovo.com/lkms, log in, and click
Help
.
To remove the system board, complete the following steps:
Step 1.
Read the safety information that begins on “Safety” on page v, “Handling static-sensitive devices”
on page 36, and “Installation guidelines” on page 34.
Step 2.
Turn off the server and any attached devices.
Step 3.
Turn off the peripheral devices and disconnect all power cords.
Removing and replacing components
339
Summary of Contents for x3650 M4 BD 5466
Page 1: ...Lenovo System x3650 M4 Installation and Service Guide Machine Type 7915 ...
Page 6: ...iv Lenovo System x3650 M4 Installation and Service Guide ...
Page 176: ...164 Lenovo System x3650 M4 Installation and Service Guide ...
Page 226: ...214 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1042: ...1030 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1200: ...1188 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1204: ...1192 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1212: ...Taiwan BSMI RoHS declaration 1200 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1221: ......
Page 1222: ......