• See the documentation that comes with an optional 2.5-inch drive backplane for device-specific
information and information about installing other components that might be included as part of the option
or about other components or modules that must be installed to use the option. For example, some
optional 2.5-inch drive backplanes might require installation of a second processor.
To install a 2.5-inch drive backplane, complete the following steps:
Watch the procedure
. A video of the installation process is available:
• Youtube: https://www.youtube.com/playlist?list=PLYV5R7hVcs-B4_LYuT9X1MRWBU6UzX9gO
• Youku: http://list.youku.com/albumlist/show/id_50481482
Figure 13. 2.5-inch drive backplane installation
Step 1. Align the backplane with the storage cage and the connector on the system board and press the
backplane into position until it is fully seated in the connector.
Note:
All 2.5-inch drive backplanes use the same connector on the system board; however, there
are two alignment slots in the storage cage to accommodate different backplane types. Make sure
that you align the backplane and system board connectors when inserting the backplane in the
storage cage.
After you install the 2.5-inch drive backplane, complete the following steps:
1. If the RAID adapter was removed, install it now. (see “Install a RAID adapter” on page 79).
2. Install any removed storage drives and drive bay fillers (see “Install a 2.5-inch hot-swap drive” on page
Note:
Install any storage drives in the same bay locations as from which they were removed.
3. Install the compute node cover (see “Install the compute node cover” on page 43 ).
4. Install the compute node into the chassis (see “Install the compute node in the chassis” on page 25 ).
5. Power on the compute node.
Air baffle replacement
Use the following information to remove and install the air baffle.
S012
30
ThinkSystem SN550 Compute Node Maintenance Manual
Summary of Contents for ThinkSystem SN550
Page 1: ...ThinkSystem SN550 Compute Node Maintenance Manual Machine Type 7X16 ...
Page 8: ...vi ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 28: ...20 ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 124: ...116 ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 128: ...120 ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 137: ......
Page 138: ...Part Number SP47A10572 Printed in China 1P P N SP47A10572 1PSP47A10572 ...