3. See the documentation for the I/O module for resolving connectivity issues.
Multiple compute nodes cannot connect to the data network (Ethernet) during initial setup
Complete the following steps until the problem is solved:
1. Make sure that:
• The I/O module is powered on and the appropriate ports are enabled on the I/O module.
• All cables between the I/O module and the network device (switch or router) are properly connected
and secure, and that the activity LEDs are lit on the appropriate ports.
2. From the compute node operating system, verify the network settings, such as IP address, subnet mask
(if using IPv4), DHCP settings, and vLAN settings, to ensure that the settings match the settings of the
network device. See the documentation for the operating system for information about checking
network settings.
3. From the compute node operating system, make sure that the network device is active. See the
documentation for the operating system for information about viewing network devices.
4. Make sure that the proper device drivers are installed for the compute node Ethernet device.
5. Check the Lenovo support Web site for any firmware updates that might apply to this issue. You can
view the release notes for a firmware update to determine the issues addressed by the update.
6. Remove the compute node from the chassis and check the connectors at the back of the node for bent
pins. If the pins are bent, contact Lenovo Support. See Removing a compute node from a chassis.
7. Install the compute node in another compute node bay to see if the problem persists. See Installing a
compute node in a chassis. If the problem persists, make sure that this compute node is connected to a
port that has been enabled and that the vLAN settings enable that port to connect to the network.
8. Check the Lenovo support Web site for any service bulletins that are related to network connectivity.
9. (Trained service technician only) Perform the following steps:
a. Force the Link/duplex speed.
b. Check the connectors on the I/O module to ensure that there are no bent pins.
c. Check the connectors on the chassis midplane to ensure there are no bent pins.
d. Remove the I/O module and install a working I/O module in the same I/O module bay.
e. If the problem is resolved, replace the I/O module that you removed.
Intermittently, multiple compute nodes cannot connect to the data network (Ethernet)
Complete the following steps until the problem is solved:
1. Using the diagnostic tools that are provided by the device manufacturer, test the I/O module that the
devices are connected to.
2. Attempt to connect one compute node to the network first, and connect other compute nodes, one by
one, to try to isolate the problem.
3. Update the I/O module firmware, if necessary.
Note:
Restarting the compute node and running POST diagnostics on the I/O module might also help
isolate the problem; however, this might have other ramifications to the network.
Ping problems
Use this information to resolve issues related to the ability to ping the CMM or an I/O module.
• “A compute node in the chassis cannot ping the CMM on management network” on page 107
• “Multiple compute nodes in the chassis cannot ping the CMM on management network” on page 107
106
ThinkSystem SN550 Compute Node Maintenance Manual
Summary of Contents for ThinkSystem SN550
Page 1: ...ThinkSystem SN550 Compute Node Maintenance Manual Machine Type 7X16 ...
Page 8: ...vi ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 28: ...20 ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 124: ...116 ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 128: ...120 ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 137: ......
Page 138: ...Part Number SP47A10572 Printed in China 1P P N SP47A10572 1PSP47A10572 ...