The result is followed by an error code or other additional information about the
error.
Viewing the test log
To view the test log when the tests are completed, select
Utility
from the top of the
screen and then select
View Test Log
. The test-log data is maintained only while
you are running the diagnostic programs. When you exit from the diagnostic
programs, the test log is cleared.
To save the test log to a file on a diskette or to the hard disk, click
Save Log
on the
diagnostic programs screen and specify a location and name for the saved log file.
Notes:
1. To create and use a diskette, you must add an optional external diskette drive to
the server before initiating the diagnostic programs.
2. To save the test log to a diskette, you must use a diskette that you have
formatted yourself; this function does not work with preformatted diskettes. If the
diskette has sufficient space for the test log, the diskette can contain other data.
Diagnostic error codes
The following table describes the error codes that the diagnostic programs might
generate and suggested actions to correct the detected problems.
If the diagnostic programs generate error codes that are not listed in the table,
make sure that the latest levels of BIOS, Remote Supervisor Adapter II SlimLine,
and ServeRAID code are installed.
In the error codes, x can be any numeral or letter. However, if the three-digit
number in the central position of the code is 000, 195, or 197,
do not
replace a
CRU or FRU. These numbers appearing in the central position of the code have the
following meanings:
000
The server passed the test. Do not replace a CRU or FRU.
195
The Esc key was pressed to end the test. Do not replace a CRU or FRU.
197
This is a warning error, but it does not indicate a hardware failure; do not
replace a CRU or FRU. Take the action that is indicated in the Action
column but
do not replace a CRU or a FRU
. See the description of
Warning
in “Diagnostic text messages” on page 169 for more information.
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447,” on page 25
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
001-xxx-000
Failed core tests.
(Trained service technician only) Replace the system
board.
001-xxx-001
Failed core tests.
(Trained service technician only) Replace the system
board.
001-250-001
Failed system board ECC.
(Trained service technician only) Replace the system
board.
170
ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual
Summary of Contents for ThinkServer RD120
Page 1: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer RD120 server Machine Types 6444 6445 6446 and 6447 Hardware Maintenance Manual ...
Page 231: ......
Page 232: ...Part Number 46U0863 Printed in USA 1P P N 46U0863 ...