Diagnostic Error Code
FRU/Action
170-197-XXX
Voltage Sensor(s) test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 47
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
170-198-XXX
Voltage Sensor(s) test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 47
2. Flash the system and re-test. See “Flash update
procedures” on page 375
3. Go to “Undetermined problems” on page 76
170-199-XXX
Voltage Sensor(s) test failed, cause
unknown
1.
See “Undetermined problems” on page 76
2. Flash the system and re-test. See “Flash update
procedures” on page 375
3. Replace component under function test
170-250-XXX 170-251-XXX
Voltage Sensor(s) Voltage
limit error
1.
Power supply
2. System board
170-254-XXX
Voltage Sensor(s) Voltage Regulator
Module error
1.
Voltage Regulator Module (VRM)
2. Microprocessor
3. System board
175-000-XXX
Thermal Sensor(s) Test Passed
No action
175-0XX-XXX
Thermal Sensor(s) failure
1.
Flash system
2. System board
175-195-XXX
Thermal Sensor(s) Test aborted by user
Information only
Re-start the test, if necessary
175-196-XXX
Thermal Sensor(s) test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
175-197-XXX
Thermal Sensor(s) test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 47
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
175-198-XXX
Thermal Sensor(s) test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Flash update
procedures” on page 375
3. Go to “Undetermined problems” on page 76
68
Hardware Maintenance Manual
Summary of Contents for ThinkCentre M55
Page 2: ......
Page 17: ...Chapter 2 Safety information 11 ...
Page 18: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 12 Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 22: ...1 2 16 Hardware Maintenance Manual ...
Page 23: ...Chapter 2 Safety information 17 ...
Page 29: ...Chapter 2 Safety information 23 ...
Page 33: ...Chapter 2 Safety information 27 ...
Page 42: ...36 Hardware Maintenance Manual ...
Page 46: ...40 Hardware Maintenance Manual ...
Page 56: ...50 Hardware Maintenance Manual ...
Page 84: ...78 Hardware Maintenance Manual ...
Page 380: ...374 Hardware Maintenance Manual ...
Page 384: ...378 Hardware Maintenance Manual ...
Page 387: ......
Page 388: ...Part Number 41X6286 Printed in USA 1P P N 41X6286 41X6286 ...