d. Lower the heat sink and press down firmly on the heat sink.
e. Align the captive screws on the heat sink with the holes on the heat-sink retention module.
f. Press down on the center of the heat sink; then, press firmly on the captive screws and tighten them,
alternating between the screws in a figure-8 pattern as illustrated on the heat sink label until they
are tightened. You can cause damage to the microprocessor if you tighten the screws on one
side first, rather than rotating. Rotate each screw one full rotation at a time. Repeat this process
until the screws are tightened.
4. If you removed the microprocessor air baffle, reinstall it (see “Replacing the microprocessor air baffle”
Note:
A microprocessor air baffle must be installed whenever the DIMM connectors closest to the
microprocessor (on the left and the right) are empty. For example, when DIMM connectors 6 and 7 are
empty on the system board, the microprocessor air baffle must be installed on microprocessor 1. This
is applicable for all microprocessors.
5. Reinstall the microprocessor and memory expansion tray, if one was removed (see “Replacing the
microprocessor and memory expansion tray assembly” on page 293).
6. Reinstall the DIMM air baffle, if one was removed (see “Replacing the DIMM air baffle” on page 221).
7. Reconnect any cables that you disconnected from the adapters or system board.
8. Reinstall the server cover (see “Replacing the server top cover” on page 216).
9. Slide the server into the rack.
10. Reconnect the power cords and any cables that you removed.
11. Turn on the peripheral devices and the server.
Thermal grease
Use this information to determine the guidelines for using thermal grease on a heat sink and microprocessor.
The thermal grease must be replaced whenever the heat sink has been removed from the top of the
microprocessor and is going to be reused or when debris is found in the grease.
When you are installing the heat sink on the same microprocessor that is was removed from, make sure
that the following requirements are met:
• The thermal grease on the heat sink and microprocessor is not contaminated.
• Additional thermal grease is not added to the existing thermal grease on the heat sink and microprocessor.
Notes:
Removing and replacing components
291
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...