Operator information
panel cable
Operator information panel
Screw
4. Install the screws to secure the operator information panel to the side of the server.
5. Slide the cable arm cover into the retention slots and install the screws to secure it on the side of
the chassis.
Note:
The cable is routed on the outside of the chassis and connected to the system board. The cable
must be protected by the cable cover on the side of the chassis.
6. Install the air baffle (see “Replacing the air baffle” on page 323).
7. Install the PCI riser-card assembly (see “Replacing a PCI riser-card assembly” on page 237).
8. If you have the optional hot-swap rear hard disk drive cage installed, rotate it down (see “Rotating the
optional hot-swap rear hard disk drive cage down” on page 181).
9. Install the server top cover (see “Replacing the server top cover” on page 321).
10. Reconnect the external cables; then, reconnect the power cords and turn on the peripheral devices
and the server.
Removing the operator information panel
Use this information to remove the operator information panel.
Note:
The server configuration you have bought may either have the operator information panel inside the
media cage or on the side of the server.
To remove the operator information panel that is inside the media cage, complete the following steps:
1. Read the safety information that begins in “Safety” on page v and “Installation guidelines” on page 36.
2. Turn off the server (see “Turning off the server” on page 26) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables as necessary to replace the device.
3. Remove the server top cover (see “Removing the server top cover” on page 320).
4. Remove the PCI riser-card assembly (see “Removing a PCI riser-card assembly” on page 235).
5. Remove the air baffle (see “Removing the air baffle” on page 322).
6. Disconnect the USB, video, CD/DVD and operator information cables from the system board. Please
remember the relevant cable routing, as you will need to reconnect them to the system board when
installing the operator information panel.
248
Lenovo System x3630 M4 Installation and Service Guide
Summary of Contents for System x3630 M4
Page 1: ...Lenovo System x3630 M4 Installation and Service Guide Machine Type 7158 ...
Page 6: ...iv Lenovo System x3630 M4 Installation and Service Guide ...
Page 14: ...xii Lenovo System x3630 M4 Installation and Service Guide ...
Page 108: ...94 Lenovo System x3630 M4 Installation and Service Guide ...
Page 134: ...120 Lenovo System x3630 M4 Installation and Service Guide ...
Page 186: ...172 Lenovo System x3630 M4 Installation and Service Guide ...
Page 844: ...830 Lenovo System x3630 M4 Installation and Service Guide ...
Page 868: ...854 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1026: ...1012 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1030: ...1016 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1038: ...Taiwan BSMI RoHS declaration 1024 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1040: ...1026 Lenovo System x3630 M4 Installation and Service Guide ...
Page 1049: ......
Page 1050: ......