LENOVO S960 Cellphone Service Manual
Page 26
Re-solder.
Re-solder.
Does PA module
(U2201) have a dry
joint problem?
Re-solder.
Does PA(U2201) have
a dry joint problem?
PA input C2208
and R2209 have
solder short
problem.
Check the calibration report
to see whether every
frequency band failed.
Is AGC calibration
normal?
Analyse
AGC at
first.
Did GSM
frequency
band fail?
DCS/PCS
frequency
band failed.
Replace
corresponding
components.
Do PA input C2207
and R2203 have solder
short problem?
Does PA(U2201)
have a dry joint
problem?
Re-solder.
Check RF receiver and transmitter MT6167(U2105) or baseband chip U1101.
Does APC circuit
(R2213) have a dry
joint problem?
Re-solder.
module’s RF input circuits are shifted, and shield bracket is short circuit.
Troubleshooting:
Note: Normally you need to re-calibrate the corresponding components after the replacement.
Y
Y
PCL calibration
failed.
N
Y
N
N
Y
N
Y
Y
Y
Y
Y
N
N
N
N
N
Y