Check whether
connections of RF cable
and fittings are reliable.
Re-connect and
calibrate.
Check whether the crystal (X2101) is fitted reversely or
has a dry joint problem.
Re-solder.
Is the separate calibration of GSM
Rx Path Loss successful?
Analyse the Rx Path Loss
problem at first.
Replace main chip MT6167(U2105) or
MT6589(U1101).
4
Radio frequency
4.1 GSM calibration during production
4.1.1
GSM AFC calibration
Problem: AFC calibration failed.
Reason: Connections of RF test cable are not reliable during the calibration. TCXO is fitted
reversely or has a dry joint problem. Receiving channel is open.
Troubleshooting:
Note: Normally you need to re-calibrate the corresponding components after the replacement.
4.1.2
GSM Rx Path Loss calibration
Problem: Rx Path Loss calibration failed.
Reason: During the calibration, connections of RF test cable are not reliable; components in
receiving channel (such as RF connectors), PA module, saw filter and peripheral capacitors have
AFC calibration
failed.
N
Y
N
Y
N
Y