Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo that can

be used in E1012 and E1024 storage expansion solutions.

Table 15. Uninterruptible power supply units

Description

Part number

RT1.5kVA 2U Rack or Tower UPS (100-125VAC)

55941AX

RT1.5kVA 2U Rack or Tower UPS (200-240VAC)

55941KX

RT2.2kVA 2U Rack or Tower UPS (100-125VAC)

55942AX

RT2.2kVA 2U Rack or Tower UPS (200-240VAC)

55942KX

RT3kVA 2U Rack or Tower UPS (100-125VAC)

55943AX

RT3kVA 2U Rack or Tower UPS (200-240VAC)

55943KX

RT5kVA 3U Rack or Tower UPS (200-240VAC)

55945KX

RT6kVA 3U Rack or Tower UPS (200-240VAC)

55946KX

RT8kVA 6U Rack or Tower UPS (200-240VAC)

55948KX

RT11kVA 6U Rack or Tower UPS (200-240VAC)

55949KX

RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)

55948PX

RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)

55949PX

For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:

http://lenovopress.com/servers/options/ups

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services

that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers

financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize

your purchase power by obtaining the technology you need today, protect against technology

obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance

their entire technology solution. We focus on making it easy to do business with us. Our highly

experienced team of finance professionals operates in a work culture that emphasizes the importance of

providing outstanding customer service. Our systems, processes and flexible policies support our goal of

providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware

and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or

months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex

transactions are serviced properly. As a premier client, you have a dedicated finance specialist who

manages your account through its life, from first invoice through asset return or purchase. This specialist

develops an in-depth understanding of your invoice and payment requirements. For you, this dedication

provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider

about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

http://www.lenovofs.com

Lenovo Storage E1012 and E1024 Disk Expansion Enclosures

18

Summary of Contents for E1012

Page 1: ... and print serving e mail and collaboration and databases Figure 1 Lenovo Storage E1012 and E1024 Disk Expansion Enclosures Did you know The E1012 and E1024 expansion enclosures offer flexible drive configurations with the choice of 2 5 inch and 3 5 inch drive form factors 10K or 15K rpm SAS and 7 2K rpm NL SAS hard disk drives HDDs and self encrypting drives SEDs and SAS solid state drives SSDs W...

Page 2: ... for various workloads Self encrypting drives with a supported RAID adapter allow clients to secure their sensitive data and to comply with various security regulations when required Designed to comply with NEBS and MIL STD requirements Designed for 99 999 availability The E1012 and E1024 are designed to support the complete range of data storage requirements from highly utilized applications to h...

Page 3: ...with global hot spares with a supported RAID adapter Redundant hardware including host ports I O modules and power supplies and fans Hot swappable and customer replaceable components including I O modules power supplies with fans and drives Components and connectors The following figure shows the front of the E1012 drive expansion enclosure Figure 2 Front view of the E1012 drive enclosure The foll...

Page 4: ...res non disruptively Drive bays E1012 12 LFF hot swap drive bays up to 8x E1012 enclosures can be daisy chained on a supported RAID adapter for a total of up to 96 LFF drives E1024 24 SFF hot swap drive bays up to 8x E1024 enclosures can be daisy chained on a supported RAID adapter for a total of up to 192 SFF drives Intermix of SFF and LFF enclosures is supported Drive technologies SAS and NL SAS...

Page 5: ...osoft Windows Server 2008 R2 2012 and 2012 R2 Red Hat Enterprise Linux RHEL 5 6 and 7 SUSE Linux Enterprise Server SLES 10 11 and 12 VMware vSphere 5 1 5 5 and 6 0 Cooling Redundant cooling with two fans that are built into power supplies Power supply Two redundant hot swap 595 W AC power supplies Hot swap parts I O expansion modules drives power supplies fans Management interfaces SAS Enclosure S...

Page 6: ...ack Power Cables Lenovo Storage SAN Rack Mount Kit Rails 25 36 Getting Started Guide Warranty Flyer Important Notices Flyer Documentation Flyer Connectivity topology The E1012 and E1024 support single and dual expansion module configurations Standard models of the E1012 and E1024 ship with one or two expansion modules see Table 2 Single module configurations can be upgraded to dual module configur...

Page 7: ...topology Dual I O module configurations can be used with 2 port RAID adapters for high availability and performance In this topology each port on the RAID adapter is connected to a different I O module chain within the same chain of dual I O enclosures Dual I O connectivity topology without enclosure redundancy is shown in the following figure Figure 6 Dual I O connectivity topology without enclos...

Page 8: ... and related connectivity options Table 4 Expansion modules and connectivity options Description Part number Feature code Max qty per one enclosure Expansion modules Lenovo Storage Expansion SAS IO Module 00WC085 AT27 2 Connectivity cables Mini SAS Host Adapter to Expansion and Expansion to Expansion External MiniSAS 8088 MiniSAS 8088 0 6m cable 00WE754 AT1A 2 External MiniSAS 8088 MiniSAS 8088 1m...

Page 9: ... 10 DWD Lenovo Storage 3 5 400GB SSD SAS 2 5 in 3 5 SSD1600MM 00WC030 AT20 12 Lenovo Storage 3 5 400GB 10DWD SAS SSD 2 5 in 3 5 1200 2 4XB7A09596 B16B 12 Table 6 SFF drive options Description Part number Feature code Maximum qty per one E1024 2 5 inch SAS hot swap HDDs Lenovo Storage 2 5 300GB 15k SAS HDD 00MM685 AT1H 24 Lenovo Storage 2 5 600GB 10k SAS HDD 00MM700 AT1K 24 Lenovo Storage 2 5 600GB...

Page 10: ...les two power cables are required per each E1012 and E1024 are listed in the following table Table 7 Part numbers and feature codes for ordering power cables Description Part number Feature code Rack power cables 1 2m 10A 100 250V 2 Short C13s to Short C14 Rack Power Cable 47C2487 A3SS 1 2m 16A 100 250V 2 Short C13s to Short C20 Rack Power Cable 47C2491 A3SW 1 5m 10A 100 250V C13 to IEC 320 C14 Ra...

Page 11: ...G267 6402 United Kingdom 10A 250V C13 to BS 1363 A 2 8m line cord 39Y7923 6215 Description Part number Feature code Physical specifications The E1012 and E1024 have the following dimensions and weight approximate E1012 Height 87 mm 3 4 in Width 447 mm 17 6 in Depth 523 mm 20 6 in E1024 Height 89 mm 3 5 in Width 447 mm 17 6 in Depth 519 mm 20 5 in Weight E1012 Minimum 16 8 kg 37 0 lb Maximum 26 6 k...

Page 12: ...al time zone Monday Friday excluding Lenovo holidays For example if a customer reports an incident at 3 00 pm on Friday the technician will arrive by 10 00 am the following Monday 9x5 next business day A service technician is scheduled to arrive at the client location on the business day after remote problem determination is completed Lenovo provides service 8 00 am 5 00 pm in the client s local t...

Page 13: ...apter Single I O module Dual I O module System x HBAs non RAID 6Gb SAS HBA 46M0907 8 No support System x RAID adapters ServeRAID M5225 2GB SAS SATA Controller 00AE938 8 4 ServeRAID M5120 SAS SATA Controller 81Y4478 8 4 ThinkServer RAID adapters ThinkServer 9286CV 8e 6Gb 8 port External SAS RAID Adapter by LSI 4XB0F28699 8 4 ThinkServer 9286CV 8e 6Gb SAS RAID Adapter by LSI 4XB0F28646 8 4 ThinkServ...

Page 14: ...47C8712 Optional PN 90Y4318 Optional PN 4XB0F28702 No Feature M5225 2GB M5120 9286CV 8e 9280 8e The 6Gb SAS HBA part number 46M0907 has the following features and specifications Form factor Low profile Controller chip LSI SAS2008 Host interface PCIe 2 0 x8 Port interface 6 Gbps SAS 3 Gbps SATA Number of ports 8 four external four internal Port connectors 1x Mini SAS x4 SFF 8088 4x SATA internal Dr...

Page 15: ...he E1012 and E1024 expansion enclosures support the following operating systems that are supported by RAID adapters and HBAs listed in RAID adapters and HBAs Microsoft Microsoft Windows Server 2012 R2 Microsoft Windows Server 2012 Microsoft Windows Server 2008 R2 Red Hat Red Hat Enterprise Linux 7 Red Hat Enterprise Linux 6 Server Edition Red Hat Enterprise Linux 6 Server x64 Edition Red Hat Enter...

Page 16: ...NEMA L6 30P line cord 00YJ776 0U 36 C13 6 C19 32A 200 240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ777 0U 21 C13 12 C19 32A 200 240V 346 415V 3 Phase PDU with IEC60309 532P6 line cord 00YJ778 0U 21 C13 12 C19 48A 200 240V 3 Phase PDU with IEC60309 460P9 line cord 00YJ779 Switched and Monitored PDUs 0U 20 C13 4 C19 Switched and Monitored 24A 200 240V 1Ph PDU w NEMA L6 30P line cord 00YJ781 0U...

Page 17: ...V Front end PDU with IEC 309 2P Gnd line cord 39Y8940 DPI 63amp 250V Front end PDU with IEC 309 2P Gnd line cord 39Y8935 Universal PDUs 7x IEC 320 C13 outlets DPI Universal 7 C13 PDU with 2 m IEC 320 C19 to C20 rack power cord 00YE443 NEMA PDUs 6x NEMA 5 15R outlets DPI 100 127V PDU with fixed NEMA L5 15P line cord 39Y8905 Line cords for PDUs that ship without a line cord DPI 30a Line Cord NEMA L6...

Page 18: ...urchase power by obtaining the technology you need today protect against technology obsolescence and preserve your capital for other uses We work with businesses non profit organizations governments and educational institutions to finance their entire technology solution We focus on making it easy to do business with us Our highly experienced team of finance professionals operates in a work cultur...

Page 19: ...enovo com Lenovo Storage E1012 Support http datacentersupport lenovo com us en products storage lenovo storage e1012 6411 Lenovo Storage E1024 Support http datacentersupport lenovo com us en products storage lenovo storage e1024 6411 Related product families Product families related to this document are the following Direct Attached Storage Lenovo Storage E1012 and E1024 Disk Expansion Enclosures ...

Page 20: ...intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties All infor...

Page 21: ... Lenovo in the United States other countries or both Lenovo ServeRAID System x ThinkServer The following terms are trademarks of other companies Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft Windows Server and Windows are trademarks of Microsoft Corporation in the United States other countries or both Other company product or service names may be tra...

Reviews: